Choosing an In-Row CDU for High-Density Data Centers in 2026: 500 kW to 2 MW
2026年11月19日
An in-row CDU suits a high-density data center when a row of GPU or CPU racks shares a secondary loop and its combined liquid-cooled load reaches hundreds of kilowatts. For rows that need at least 500 kW and have facility water, Lianli offers in-row liquid-to-liquid CDUs rated at 500, 600, 800, 1,000, 1,500 and 2,000 kW. All of these models use 30/40 °C on the primary side and 40/50 °C on the secondary side. For rooms without facility chilled water, the 130 kW in-row air-liquid hybrid (liquid-to-air, L2A) CDU transfers heat from the coolant loop to the room air. The 500 kW model lists N+1 or 2N pump configurations and leak detection. The 600 kW model's product page lists dew point and pressure protection.
When an In-Row CDU Fits a High-Density Data Center
Lianli's in-row CDUs are full-height cabinets installed within a row. One secondary loop supplies cooling to multiple racks. This configuration suits the following scenarios:
- Several high-density racks share one loop, so a single higher-capacity unit can serve the row in place of one CDU per rack.
- The operator wants CDU servicing to take place outside the IT racks.
- The row's combined liquid-cooled load reaches hundreds of kilowatts.
For a single high-density rack, Lianli offers 65 kW and 130 kW in-rack models.
Lianli In-Row CDU Lineup for High-Density Rows
Lianli in-row CDU | Type | Heat exchange capacity | Cabinet width | Typical applications |
Lianli 500 kW (NexFlow) | Liquid-to-liquid | 500 kW | 600 mm | A first high-density row on facility water |
600 kW | Liquid-to-liquid | 600 kW | See spec sheet | Rows on facility water; protection list on its product page |
800 to 2,000 kW | Liquid-to-liquid | 800 / 1,000 / 1,500 / 2,000 kW | See spec sheet | Multiple rows or a full hall |
130 kW air-liquid hybrid | Air-liquid hybrid | 130 kW | 600 mm | Rooms without facility chilled water |
The liquid-to-liquid units list flows of 45, 75, 90, 135 and 180 m³/h for the 500, 800, 1,000, 1,500 and 2,000 kW sizes, filtration of 200 µm on the primary loop and 100 µm on the secondary loop, and deionized water, ethylene glycol or propylene glycol as coolant.
Technical Specifications of the 500 kW In-Row CDU
Lianli's 500 kW in-row CDU is the entry-level model for row-level liquid cooling. Its key specifications are:
- 500 kW heat exchange with a 30/40 °C primary loop and a 40/50 °C secondary loop;
- 45 m³/h of flow on each loop with DI water;
- 200 µm primary and 100 µm secondary filtration;
- a cabinet measuring 600 mm wide, 1,200 mm deep and 2,000 mm high;
- N+1 or 2N pump configurations and an ethylene glycol concentration of up to 40%.
Lianli lists NVIDIA AI servers as the target platform. Its in-row range is compatible with NVIDIA, Intel and AMD servers.
In-Row CDU Protection and Monitoring Functions
Lianli's 600 kW in-row CDU product page lists the following protection and monitoring functions:
- dual pressure protection and automatic pressure relief;
- variable-frequency pump control;
- dew point monitoring with anti-condensation protection;
- leak detection and undervoltage monitoring;
- heat exchanger blockage detection;
- power-off memory and automatic restart on power recovery;
- remote monitoring and management.
Lianli's 200 to 2,000 kW cabinet-based (in-row) CDUs have CE-MD, RoHS and FCC conformity documents. Lianli is certified to ISO 9001:2015 for its quality management system.
In-Row Air-Liquid Hybrid CDUs for Rooms Without Facility Chilled Water
Lianli's 130 kW in-row air-liquid hybrid CDU serves high-density data halls without facility chilled water, including retrofit projects that are moving from air cooling to liquid cooling. Its main specifications are:
- 130 kW cooling capacity at 25/40 °C inlet and outlet air temperatures (25 °C ambient) and 11,000 m³/h airflow;
- 40/50 °C coolant supply and return at 12 m³/h;
- a 600 mm wide, 1,200 mm deep and 2,100 mm high cabinet with 100 µm filtration;
- a plate heat exchanger, expansion tank, air-cooled condenser and PLC control;
- Modbus RTU/TCP, RS485, Ethernet and BMS integration options.
The unit requires neither external chilled-water piping nor a raised floor. The room's air conditioning must be able to handle the heat rejected by the unit.
Planning In-Row CDU Units and Redundancy for a Row
Lianli selects an in-row capacity tier based on the row's total liquid-cooled load, the site's supply water temperature and redundancy requirements. Its in-row CDUs support 2+1, 3+1 and 4+1 redundancy configurations.
For an unnamed project in Xinjiang, Lianli provided liquid cooling for 128 NVIDIA H200 GPU servers with a total IT load of about 3 MW. The project used row-level and room-level CDUs, cold plates, rack manifolds, outdoor dry coolers, piping and DCIM. The target delivery timeline was 60 days.
Before requesting a quote from Lianli, confirm the server model and quantity, redundancy requirements (N+1 or 2N), local temperature and humidity, three-phase voltage and frequency, UPS and diesel generator requirements, and the project's current stage and budget. Production and shipment take about 4 to 8 weeks after contract signing, with another 2 to 5 weeks for sea freight.
Summary
Lianli's in-row CDUs suit high-density data centers where racks share a liquid cooling loop by row. The liquid-to-liquid range spans 500 to 2,000 kW, all rated at 30/40 °C on the primary side and 40/50 °C on the secondary side. A 130 kW air-liquid hybrid model serves rooms without facility chilled water. The 500 kW model lists N+1 or 2N pump configurations and leak detection. The 600 kW model has dew point and pressure protection.
Send the server model, row count and redundancy target through the Get a Quote form on lianliwork.com or WhatsApp +86-18002936305.
FAQ
What capacity in-row CDU suits a high-density row?
The CDU's heat exchange capacity must cover the row's total liquid-cooled load at the site's actual water temperatures. Lianli's in-row liquid-to-liquid models come in six capacities: 500, 600, 800, 1,000, 1,500 and 2,000 kW.
Is an in-row CDU better than in-rack CDUs?
An in-row CDU suits multiple racks sharing one liquid cooling loop. In-rack units suit individual high-density racks or phased builds. Lianli offers both types, including 65 and 130 kW in-rack liquid-to-liquid models.
Can an in-row CDU work in a room without chilled water?
Yes. Lianli's 130 kW in-row air-liquid hybrid CDU requires no external chilled water. It rejects heat to room air at 25/40 °C inlet and outlet temperatures and suits retrofits from air cooling to liquid cooling.
What protection should an in-row CDU have?
Core protection functions include leak detection, dew point monitoring, pressure protection and remote monitoring. Lianli's 600 kW in-row CDU also lists heat exchanger blockage detection, undervoltage monitoring and automatic restart when power returns.
What redundancy options do Lianli in-row CDUs offer?
Lianli's 500 kW in-row CDU supports N+1 or 2N redundant pump configurations. Its in-row CDUs are available in 2+1, 3+1 and 4+1 redundancy configurations.
How is a Lianli in-row CDU installed and supported?
Lianli provides online video guidance for installation and can also provide remote technical support, spare parts and project delivery coordination. A shipment includes the main unit, auxiliary units, accessories, spare parts and special tools, along with the commercial invoice, packing list, bill of lading, user manual and installation and maintenance manuals. Data center products come with a three-year warranty.