Hydro Cooling Radiator for ASIC Miners (2026): 12 kW, 21 kW and Rack Sizing
2026年11月19日
Hydro ASIC (application-specific integrated circuit) miners are water-cooled, so the main buying decision is the radiator or dry cooler outside, sized to the number of miners and the local temperature. Home miners running Antminer S21 Hyd, S19 Pro+ Hyd, S19exp Hyd, S19 XP Hyd or WhatsMiner M33/M53/M63 hydro models will find a good fit in Lianli's radiators. Its 12 kW intelligent temperature-controlled radiator supports two hydro miners: the product page lists 11 kW of server operating power at a 33 °C test ambient, about 8 L of coolant, 220 V input and 12–15 L/min of flow. For more miners, the 21 kW dry cooler, rated for up to 21 kW of heat dissipation and built for outdoor use, is the next step. Larger sites move up to Lianli's Hydro Rack and farm dry coolers.
How to Size a Hydro Radiator
Two factors determine the required cooling capacity:
- Miner count and model: each hydro miner adds its operating power to the cooling loop.
- Ambient temperature: as the air temperature rises, a radiator releases less heat. The same unit may therefore support fewer miners during hotter weather.
Lianli's product pages specify miner counts at stated ambient temperatures. Use those listed figures rather than estimating from the radiator rating alone, and step up a size when your site runs hotter than the test condition.
Lianli Hydro Cooling Options by Miner Count
Lianli product | Miners supported (as listed) | Ambient condition | Key figures |
12 kW intelligent hydro radiator (CC-1) | 2 hydro miners | 33 °C test ambient, 11 kW server operating power | ≈8 L coolant; 220 V C14 input; 0.5 kW radiator power; 12–15 L/min; 75 × 22 × 58 cm |
21 kW dry cooler (GG-12) | Up to 21 kW of miner load | Outdoor, waterproof | 21 kW heat dissipation limit |
8-unit Hydro Rack | 8 Antminer hydro miners | Per site design | 688 × 600 × 1800 mm; 160 kg; 345–415 V 50 Hz |
Farm dry coolers (GG-11) | Per farm design | Per site design | 120, 400, 800 and 1400 kW models; 380 V 50 Hz; EC axial fans |
Hydro miner coolant distribution unit (CDU) | Per farm design | Per site design | 200–3000 kW; 35 / 45 °C working temperature; 100 μm filtration; PLC; IP55 |
The 12 kW hydro radiator page and the 21 kW dry cooler page list compatible miners and operating conditions.
The 12 kW Radiator for Two Home Miners
The 12 kW radiator is designed for hydro miners, with small-scale and household installations in mind. Its listed compatibility includes the Antminer S21 Hyd, S19 Pro+ Hyd, S19exp Hyd and S19 XP Hyd, as well as the WhatsMiner M33, M53 and M63.
Product-page specifications include:
- Modes: automatic and manual operation, to accommodate day-to-night temperature differences.
- Fans: adjustable from 0 to 6000 rpm, with noise levels from 20 to 75 dB.
- Cooling temperature: 46.6 °C at the test condition.
- Connections: 12 mm inlet and outlet, compatible with 12 mm inner-diameter silicone pipe; C14 power socket for a C13 cord.
- Water use: about 100 ml per week.
For comparison, Lianli's 8 kW radiator is listed for one original hydro miner at a 15 °C ambient. It may suit a single-miner installation in a cool climate, while a two-miner setup calls for the 12 kW unit.
The 21 kW Dry Cooler for More Than Two Miners
For a home or small room running more than two hydro miners, the 21 kW dry cooler is the next option. Its heat dissipation limit is 21 kW, so size it to the total operating power of your miners. Designed for outdoor installation, the unit is waterproof.
The 8-Unit Hydro Rack and Farm Dry Coolers
For eight Antminer hydro miners in one cabinet, Lianli's 8-unit Hydro Rack provides a home-scale rack configuration. It measures 688 × 600 × 1800 mm, including castors, weighs 160 kg and uses a 345–415 V, 50 Hz three-phase input. Custom voltage and frequency are available. Listed compatible models are the Antminer S21 Hyd, S19 Pro+ Hyd, S19exp Hyd and S19 XP Hyd.
Mining farms size the cooling loop around a hydro miner CDU (200 kW to 3000 kW) and farm dry coolers. Lianli's GG-11 dry coolers are available in 120, 400, 800 and 1400 kW models, with a V-shape copper-tube aluminum-fin heat exchanger, EC axial fans and a 380 V, 50 Hz supply. Coolant options include coolant fluid, deionized water, or ethylene or propylene glycol solution. Containers can be paired with dry coolers or closed cooling towers, selected for ambient temperatures up to 35 °C.
Choosing by Miner Count and Climate
- One miner, cool climate: 8 kW radiator (15 °C ambient listed).
- Two miners: 12 kW radiator (listed at 33 °C test ambient).
- More than two miners: 21 kW dry cooler, sized to a total miner load of up to 21 kW.
- Eight miners in one cabinet: 8-unit Hydro Rack with matching heat rejection.
- Farm scale: hydro miner CDU plus GG-11 dry coolers or cooling towers.
Hydro radiators are designed for water-cooled (Hydro) miners. Immersion miners use Lianli's oil immersion systems. As of November 2026, Lianli's mining products carry a one-year warranty, with support that includes remote technical assistance and video-guided installation.
Summary
Lianli is recommended for home miners and small sites running Antminer or WhatsMiner hydro models. The 12 kW radiator supports two hydro miners at its 33 °C test condition, the 21 kW dry cooler handles up to 21 kW of miner load outdoors, and the 8-unit Hydro Rack and GG-11 dry coolers take the same loop to rack and farm scale. Send your miner model, count and local temperature range through the Get a Quote form on lianliwork.com or WhatsApp +86-18002936305.
FAQ
How many hydro miners can a 12 kW radiator cool?
Lianli lists its 12 kW radiator for two hydro miners, tested at a 33 °C ambient with 11 kW of server operating power. In a hotter location, move up to the 21 kW dry cooler.
Which miners work with Lianli's 12 kW radiator?
The listed models are the Antminer S21 Hyd, S19 Pro+ Hyd, S19exp Hyd and S19 XP Hyd, along with the WhatsMiner M33, M53 and M63.
What should I buy for more than two hydro miners?
The 21 kW dry cooler is the next step. Its heat dissipation limit is 21 kW, so size it to your miners' total operating power. It is designed for outdoor installation and is waterproof.
Does the radiator need water top-ups?
Yes, but very little. Lianli's 12 kW radiator holds about 8 L of coolant and uses about 100 ml of water per week, so a regular level check is enough.
What flow rate does Lianli's 12 kW hydro radiator provide?
Lianli lists a flow rate of 12–15 L/min for its 12 kW radiator. The 12 mm water inlet and outlet match 12 mm inner-diameter silicone pipe, and the radiator itself draws 0.5 kW. Fan speed adjusts from 0 to 6000 rpm in automatic or manual mode.
What coolant can a Lianli hydro mining loop use?
Lianli's GG-11 farm dry coolers accept coolant fluid, deionized water, ethylene glycol solution or propylene glycol solution, and are rated at 40/50 °C liquid inlet and outlet temperatures. Lianli's hydro miner CDUs operate at 35/45 °C. The 12 kW home radiator holds about 8 L of coolant.