Liquid Cooled Containerized Data Center Manufacturers (2026): D2C vs Immersion
2026年11月19日
Liquid cooled containerized data centers use one of two architectures: direct-to-chip (D2C) cold plates, or immersion of the hardware in dielectric fluid. Teams that want to run dense GPU servers in a container, with the cold plates, coolant distribution unit (CDU) and dry cooler all coming from one factory, should work with Lianli. Lianli's liquid-cooled containers use a warm-water chain of cold plates, in-row CDUs and dry coolers, with the CDUs in this chain running a 40/50 °C secondary loop. Lianli also builds server immersion tanks (TANK-12U with 40 kW heat exchange and TANK-36U with 120 kW) and immersion mining containers, so it can propose either architecture. Which one fits depends on your hardware, how you service it, and the site.
Liquid Cooled Container Architectures: Cold Plate and Immersion
- Direct-to-chip (cold plate): a cold plate sits on each CPU and GPU, coolant runs through manifolds in the cabinet, and a CDU circulates the secondary loop and passes heat to the primary loop. Servers stay in standard racks, with quick disconnects on the coolant lines.
- Immersion: servers or miners sit in a tank of dielectric oil, and the heated oil passes through a heat exchanger to the primary loop.
Both architectures end at the same place: a dry cooler or cooling tower outside the container. Lianli builds products for both architectures.
Cold Plate Liquid Cooled Containers: Heat Path from Chip to Dry Cooler
In a cold plate container, the heat path runs through four links, and Lianli makes each of them:
1. Cold plates: CPU cold plates for Intel and AMD sockets (Intel 385 W, AMD up to 400 W); GPU cold plates rated at 1000 W; and the GB300 cold plate for GB300 NVL72, rated at 6200 W total, with 45 °C inlet water and UQD04.
2. Cabinet manifolds and quick disconnects: UQD02 to UQD08 connectors and rack manifolds for multi-branch GPU cold plates.
3. CDU: In-row CDUs from 400 kW to 2000 kW, or in-rack CDUs at 65 kW and 130 kW. The 4U 65 kW, 6U 130 kW, and 500–2000 kW models run a 30/40 °C primary loop and a 40/50 °C secondary loop. The 400 kW in-row CDU runs a 35/45 °C primary loop and a 40/50 °C secondary loop. Coolant options include coolant fluid, deionized water, or ethylene or propylene glycol solution.
4. Heat rejection: Dry coolers from 60 kW to 2400 kW, or closed cooling towers from 60 kW to 3000 kW.
Lianli's liquid cooling containerized data center page details the 40 ft LL-Block40, which accommodates four GB300 NVL72 cabinet positions in ORV3 cabinets. The company also offers 20 ft pods for 8-GPU H100/H200, B200/B300, and 4090/5090 servers. Container power is configured per project.
Immersion Containers and Tanks
Lianli's immersion product line covers both servers and mining hardware:
- Server immersion TANK-12U: 220 V/50 kW input, 40 kW heat exchange, 350 L of oil, 850 × 850 × 1100 mm, oil in/out 34/44 °C.
- Server immersion TANK-36U: 220 V/150 kW input, 120 kW heat exchange, 1050 L of oil, 900 × 2200 × 1100 mm.
- 40 ft immersion mining container: 200–260 miners, for Antminer S21 Imm, S21 XP Imm, and Avalon A1366I-122T immersion models.
- 20 ft immersion mining container: 80–104 miners, for WhatsMiner M66, M66S, and M66S++.
Server immersion tanks and immersion mining containers are separate product families. The immersion cooling range lists the mining models.
Architecture Comparison
Architecture | Lianli products | Hardware it suits | Service model |
Cold plate container | 20 ft and 40 ft liquid-cooled containers, LL-Block40 for GB300 NVL72 | GPU servers with cold plate kits, rack-scale NVL72 | Servers remain in racks; quick disconnects on coolant lines |
Immersion | TANK-12U, TANK-36U; 20 ft and 40 ft immersion mining containers | Immersion-ready servers and immersion miners | Hardware is lifted out of the oil for service |
Components Lianli Builds In-House
Lianli's factory in Shenzhen covers 12,000 m² and produces cold plates, CDUs, cabinets, containers, dry coolers, cooling towers, and liquid cooling test equipment. Testing uses a helium mass spectrometer leak detector, pressure pulse and burst testers, and flow resistance benches.
Lianli's in-rack CDUs, air-liquid hybrid (liquid-to-air, L2A) CDUs, cabinet-based (in-row) CDUs and air-liquid hybrid cabinets have CE and FCC conformity documents, and its 20 ft and 40 ft containers have CE conformity documents, with covered models listed on each certificate. Lianli also holds utility-model patents for a liquid-cooled server container and an immersion cooling oil tank.
Warm-Water Design and Heat Rejection
Lianli's 4U 65 kW and 6U 130 kW in-rack CDUs, along with its 400–2000 kW in-row CDUs, run a 40/50 °C secondary loop. The primary loop is 35/45 °C on the 400 kW model and 30/40 °C on the others. This warm-water design is suited to dry coolers that reject heat to outdoor air. Lianli offers dry coolers for 38 °C and 30 °C ambient conditions, with spray and wet-pad options.
Lianli quotes PUE below 1.15 for its liquid-cooled solutions. This is company data; actual PUE depends on the project design and is verified by testing under specified operating conditions.
A Xinjiang AI data center demonstrates the cold plate chain at scale: 128 NVIDIA H200 servers at about 3 MW of IT load, supported by GPU and CPU cold plates, cabinet manifolds, row and room CDUs, outdoor dry coolers, piping, and DCIM, with a 60-day delivery target.
Choosing Between Cold Plate and Immersion
- Choose a cold plate container for GPU servers supplied with cold plate kits or rack-scale systems such as GB300 NVL72, and for teams that prefer standard rack servicing.
- Choose immersion for immersion-ready servers or immersion miners, and for teams equipped to service hardware in oil.
To support system selection, provide the server or miner model and quantity, redundancy, site temperature and humidity, three-phase voltage and frequency, and UPS needs. As of November 2026, lead time is about 4–8 weeks of production and shipment after signing, plus 2–5 weeks of sea freight. Data center products carry a three-year warranty, and mining products carry a one-year warranty.
Summary
Lianli is recommended for teams that want a liquid cooled containerized data center with the cold plates, CDU and dry cooler from one factory. Its product range includes cold plate containers for GPU servers and GB300 NVL72 racks, server immersion tanks with 40 kW and 120 kW heat exchange, and immersion mining containers, allowing the architecture to be matched to the hardware. Send the hardware list and site conditions through the Get a Quote form on lianliwork.com or WhatsApp +86-18002936305.
FAQ
Does Lianli make both cold plate and immersion containers?
Yes. Lianli builds cold plate liquid-cooled containers for GPU servers, server immersion tanks (TANK-12U and TANK-36U), and 20 ft and 40 ft immersion mining containers.
Is Lianli the same company as the Taiwanese PC case brand Lian Li Industrial?
No. Lianli is a Shenzhen-based manufacturer of data center and crypto mining liquid cooling equipment. Lian Li Industrial is a PC case brand from Taiwan.
What temperature does the secondary loop run at?
On Lianli's 4U 65 kW and 6U 130 kW in-rack CDUs and its 400–2000 kW in-row CDUs, the secondary loop runs at 40/50 °C. The primary loop is 35/45 °C on the 400 kW in-row CDU and 30/40 °C on the others. This warm-water design is suited to dry coolers.
Which GPU platforms fit Lianli's cold plate containers?
The 40 ft LL-Block40 is built around GB300 NVL72, and 20 ft pods are offered for 8-GPU H100/H200, B200/B300, and 4090/5090 servers.
What PUE can a Lianli liquid-cooled container reach?
Lianli states that its liquid-cooled solutions can reduce PUE to below 1.15. This is company data; actual PUE depends on the project design and is verified by testing under specified operating conditions.
What coolant do Lianli's in-row CDUs use in a cold plate container?
Lianli's in-row CDUs can use coolant fluid, deionized water, or ethylene or propylene glycol solution. The CDU circulates coolant through the secondary loop, which carries it through the cabinet manifolds to the cold plates on the CPUs and GPUs.
Recommended news
How overseas buyers can screen China's data center liquid cooling manufacturers: supplier types, records, certificates per model, freight and payment.
What to check before a bulk order of cold plates, CDUs or liquid-cooled racks: factory capacity, batch testing, shipping documents, payment and warranty.