48U Liquid-Cooled Server Rack | Air-to-Liquid Cooling Solution
The Lianli 48U liquid cooled server rack completely breaks through the power density limit of traditional air cooling through its revolutionary dual-mode cooling architecture: its intelligently switched liquid cooling module (supports single-phase immersion/cold plate) efficiently dissipates heat, while the redundant EC fan wall ensures 35kW-level uniform air cooling coverage, achieving a total cooling capacity of 55kW for a single cabinet; reducing PUE to below 1.15, reducing cooling electricity costs by 50%. At the same time, the military-grade reliable design (IP42 protection) and zero-modification compatibility allow customers to reduce TCO by 45% and safely carry critical loads such as AI training clusters and GPU supercomputing.

Product Specifications
| Item | Air-Liquid Hybrid Cabinet 35kW | Air-Liquid Hybrid Cabinet 55kW |
|---|---|---|
| Application | General DCs (CPU/GPU Servers), Edge Computing Nodes, Industrial Lasers, Energy Storage Systems | |
| Cooling Capacity | 35 kW | 55 kW |
| Supply & Return Water Temperature | 40 ~ 50 °C | |
| Supply & Return Water Flow Rate | 3.3 m³/h | 4.5 m³/h |
| Medium | Deionized Water / Ethylene Glycol / Propylene Glycol | |
| Dimensions (W×D×H) | 600 × 1350 × 2200 mm | 600 × 1350 × 2200 mm |
| Air Intake Rate | 1300 m³/h | 1700 m³/h |
| PDU | 380V 16A, 20Units | |
| Manifolds | UQD04 Male Connectors × 20pcs | |
| Distribution Manifold | 2 pcs | |
Why Professionals Choose the 48U Liquid-Cooled Server Rack
1. High-Density Thermal Management
As CPU and GPU TDPs exceed 400W–700W, traditional air cooling faces "thermal runaway." Our Air-to-Liquid design utilizes high-performance heat exchangers to capture heat at the source, ensuring components remain within optimal T-junction temperatures even under 100% load.
2. Seamless Facility Integration
Unlike "Liquid-to-Liquid" systems that require dedicated secondary water loops, the Air-to-Liquid configuration can exhaust heat back into the hot aisle or integrate with existing CHW (Chilled Water) lines. This makes it the ideal choice for brownfield data center upgrades.
3. Redundancy & Reliability
- Leak-Free Technology: Equipped with industrial-grade, non-drip quick-connect couplings.
- N+1 Power & Cooling: Dual power feeds and redundant pump configurations within the CDU (Cooling Distribution Unit).
- Real-Time Telemetry: Full integration with DCIM (Data Center Infrastructure Management) via SNMP or Modbus.
Optimized for Modern Hardware
Specifically designed to house and cool power-hungry server architectures, including:
- NVIDIA HGX™ / DGX™ H100/H200, B100/B200, GB200/GB300 platforms.
- Intel® Xeon® Scalable and AMD EPYC™ high-core-count nodes.
- Multi-node storage arrays and high-speed networking switches.
Get a Technical Consultation
Ready to modernize your infrastructure? Contact our systems engineers to discuss flow rates, PUE reduction, and rack-level CDU compatibility.
Return And Exchange Policy:
1. Domestic customers: Within 7 days of receiving the goods, our quality department confirms that it is a product quality problem;
2. Overseas customers: Within 15 days of receiving the goods, our quality department confirms that it is a product quality problem;
3. The outer packaging is damaged, and abnormalities occurring during transportation are not within the scope of return or exchange (please contact the freight company for claim settlement, and our company can assist with claim settlement);
4. We only provide after-sales service to customers who purchase directly. If you purchase our products from a dealer or a third party, please contact the seller for after-sales service;
5. The product cannot be disassembled after receipt, and cannot be modified or repaired without our permission. Keep the outer packaging and keep the labels intact, otherwise no after-sales service will be provided.