搜索历史清除全部记录
最多显示8条历史搜索记录噢~
全部
  • 全部
  • 产品管理
  • 新闻资讯
  • 介绍内容
  • 企业网点
  • 常见问题
  • 企业视频
  • 企业图册

Nauru 40FT Liquid-Cooled Containerized Data Center | Modular/Prefabricated Data Center | Nvidia GB300 NVL72

Liquid-Cooled Containerized Data Center | 40FT

Category:

NauruProduct Display

NauruData Center Liquid Cooling System

NauruContainer Data Center

Phone:+86-400-852-9767

Product Description

Liquid-Cooled Containerized Data Center | Compatible With All NVIDIA/AMD/Intel Server Models

40-foot liquid-cooled data center container is a modular, prefabricated, and mobile data center that highly integrates servers, liquid cooling systems, and auxiliary infrastructure within a standard shipping container.

 

Its unique liquid cooling technology enables rapid, efficient deployment and is compatible with all major server brands on the market, such as NVIDIA, AMD, Intel, and Huawei.  It is particularly well-suited for NVIDIA models—including the GB300, GB200—ensuring high-performance operation that meets demanding computational requirements.


This container operates reliably in high-temperature environments and achieves a PUE as low as 1.15, Compared to traditional air-cooled data centers, it significantly reduces energy consumption and achieves a lower PUE, while supporting ultra-high rack power densities and stable 24/7 operation. It holds dual CE and UL certifications, ensuring safety and compliance, and delivers outstanding support across data centers, cloud computing facilities, and other high-performance computing applications.


The container structure is engineered for industrial-grade durability, offering excellent protection against dust, humidity, corrosion, and vibration. With optimized internal layout and scalable cooling capacity, the solution maximizes computing performance per square meter and minimizes operational noise and maintenance costs.

 

The 40ft containerized design enables factory-level integration and on-site plug-and-play deployment, greatly shortening construction timelines and reducing upfront investment. Flexible configuration options allow customization of computing capacity, cooling architecture, and power systems to match specific project requirements, making it ideal for rapid capacity expansion, edge data centers, remote deployments, and temporary or modular data center projects.

 

 

 

Product Specifications

ItemSpecification
Product ModelLL-Block40
Container Specification40HQ Container
Performance ParametersSpecification
Internal Container Dimensions (L×W×H)1200 × 2350 × 2700 mm
IT Cabinet ConfigurationNvidia GB300 NVL72 × 4 Units
Supported IT Cabinet Power≤ 150 kW per Cabinet
CabinetSpecification
Cabinet Dimensions (L×W×H)600 × 1200 × 2200 mm
Available IT Space per CabinetORV3 standard
Temperature controlSpecification
Air Conditioning SystemPumped Refrigerant In-Row AC with External Dry Cooler
Cooling ConfigurationSplit-Type Pumped Refrigerant AC, 70 kW per Cabinet, 210 kW Total (3 Units)
CategoryDescription
Power SupplyPower Supply Framework: N+1Input Power Supply Mode: 380VAC, 50HzUPS Method: Cold plate liquid cooling, modular UPS + backup battery + integrated power supplySystem Backup Time: 720KW/15 minutes (Battery backup time does not exceed 90 days; if so, it requires charging)
Power Supply MonitoringMonitoring Interface: 15.6-inch touch screen, webpage, client-side, APPEnvironmental Monitoring: Air conditioning, power supply, UPS, temperature, leakage, smoke, door status, fire alarm interactionIntelligent Monitoring: Battery inspection, video surveillance, electronic door control, asset management, volume management, external intelligent network interaction, multi-site centralized management, GPS positioning management, 3D visualization
Fire SafetyFire Extinguishing Method: Seven-gas automatic fire extinguishing systemFire Detection System: Smoke detection, fire alarm system, emergency manual control switch, post-exhaust smoke system, early smoke detection system (Washing System)

 

Benefits Of Container Data Center Liquid Cooling

  • Rapid Deployment & Flexibility
    Pre-engineered and factory-tested units can be deployed in weeks instead of months, offering fast and flexible deployment. The system is designed for easy relocation or redeployment, ensuring adaptability as operational needs change. It is fully compatible with NVIDIA’s GB300, GB200, B300, B200, H100, H200 ,Pro6000 models, providing a ready-made solution for AI workloads and high-performance computing (HPC) requirements from day one.
  • Energy-Efficient & Cost-Effective
    Advanced liquid cooling technology dramatically reduces cooling power consumption, lowering energy bills and total cost of ownership compared to traditional air-cooled data centers. By optimizing thermal management, this solution delivers superior energy efficiency—especially when running high-power IT loads from NVIDIA systems such as the GB300 and H200—leading to significant savings in operational costs.
  • High-Density Scalability
    This solution supports high-power IT loads and scales effortlessly by adding modular containers, enabling fast capacity expansion without major site modifications. As your business grows and the demand for NVIDIA-powered computing expands, the system can be easily upgraded to support multiple GPUs and AI clusters with GB200, B300, and B200 models for next-generation computing tasks.
  • Reliable in Extreme Environments
    The sealed container design, combined with cutting-edge liquid cooling, ensures stable performance even in extreme environments, including high temperatures, dusty conditions, and remote or harsh locations. Whether deploying in a remote edge computing site or in regions prone to environmental stress, the solution offers reliable operation for NVIDIA’s high-performance hardware such as the B200 and GB300 models.
  • Compact & Portable Design
    Designed for flexibility and space efficiency, this solution is perfect for edge computing, AI workloads, disaster recovery, and temporary deployments where space, power efficiency, and rapid mobility are critical. The compact containerized system can be moved quickly to new locations, enabling businesses to expand their NVIDIA-powered infrastructure without the constraints of traditional data center setups.

 

 

Why Liquid Cooling + Containerization?

MetricTraditional Air-Cooled Data Center40ft Liquid-Cooled Container
Max Rack Density10–15kW/rack (airflow-limited)100kW+/rack
PUE (Power Usage Effectiveness)1.5–1.8As low as 1.05
Deployment Timeline12–24 months (construction + permits)4–6 weeks (factory to production)
Energy EfficiencyBaseline30–50% less energy vs. air cooling
Space EfficiencyConventional footprint90% space reduction possible
On-Site InstallationExtensive civil + mechanical workPlug & Play — just connect power and water
Environment ImmunitySensitive to dust, humidity, temperatureSealed system — immune to dust, 50°C ambient
Total Cost of Ownership (TCO)Baseline25–40% lower TCO

 

 

Choosing the Right Liquid-Cooled Containerized Data Center 

When choosing a data center container, it's important to consider the following factors:

  • Capacity: Determine the power and cooling capacity you need for your IT equipment.
  • Size: Choose a container size that fits your available space and deployment requirements.
  • Features: Select a container with the features you need, such as advanced security measures or specific cooling options.
  • Vendor Reputation: Choose a reputable vendor with a proven track record of delivering high-quality data center containers.
  • Cost: Compare prices from different vendors to find the best value for your budget.

 

 

The Deployment Process for Data Center Containers

The deployment process for data center containers typically involves the following steps:

  • Site Preparation: Prepare the deployment site by ensuring adequate power, cooling, and network connectivity.
  • Container Delivery: Deliver the data center container to the site.
  • Installation: Install the container on the site and connect it to power, cooling, and network resources.
  • Testing and Commissioning: Test the container to ensure that all components are working correctly.
  • Equipment Installation: Install your IT equipment into the container.
  • Go-Live: Activate the data center container and begin using it to power your business.

 

Lian Li Liquid-Cooled Data Center Container Services

  • Site Assessment and Planning: Assistance with evaluating deployment sites and planning the installation of data center containers.
  • Customization and Integration: Customizing data center containers to your specific requirements and integrating them with your existing infrastructure.
  • Installation and Commissioning: Professional installation and commissioning services to ensure a smooth deployment.
  • Maintenance and Support: Comprehensive maintenance and support services to ensure the smooth operation of your data center containers

 

Liquid-Cooled Data center containers offer a compelling solution for businesses looking to quickly deploy scalable and efficient data center infrastructure. By understanding the advantages, components, and key considerations, you can make an informed decision and choose the right data center container for your needs.

Contact us today to learn more about our data center container solutions. Our team of experts is ready to help you find the right solution for your business.

 

 

 

SHIPPING DETAILS

1. Shipments will be scheduled on a first-paid-first-ship basis for orders on which lianli has received full payment.

2. You are responsible for any customs delays or returned shipments due to a lack of proper documentation. It's highly recommended to be aware of local customs clearance policies and prepare all customs documentation ahead of time to avoid delays or unexpected costs.

 

Return and exchange policy:

1. Domestic customers: Within 7 days of receiving the goods, our quality department confirms that it is a product quality problem;
2. Overseas customers: Within 15 days of receiving the goods, our quality department confirms that it is a product quality problem;
3. The outer packaging is damaged, and abnormalities occurring during transportation are not within the scope of return or exchange (please contact the freight company for claim settlement, and our company can assist with claim settlement);
4. We only provide after-sales service to customers who purchase directly. If you purchase our products from a dealer or a third party, please contact the seller for after-sales service;
5. The product cannot be disassembled after receipt, and cannot be modified or repaired without our permission. Keep the outer packaging and keep the labels intact, otherwise no after-sales service will be provided.