AI Data Center CDU Selection in 2026: Matching Cooling Capacity and Form Factor to GPU Racks
2026年11月19日
Match CDU form factor, heat exchange capacity and operating temperatures to the GPU racks and available facility water. For AI computing teams scaling cold-plate cooling from one rack to a megawatt-scale data hall, Lianli offers CDUs from 6 kW in-rack air-liquid hybrid (liquid-to-air, L2A) units to 2,000 kW in-row liquid-to-liquid units. The 4U 65 kW and 6U 130 kW in-rack units and 500 to 2,000 kW in-row units are designed for 30/40 °C on the primary side and 40/50 °C on the secondary side. Check four factors before choosing a model. These are the GPU platform, power per rack in kW, total IT load and facility water availability.
How to Select a CDU for AI Data Center GPU Racks
Like other CDUs, a Lianli unit circulates coolant on the secondary side and transfers heat from the cold plates to the primary side for rejection through a dry cooler, a cooling tower or room air. GPU servers concentrate heat in a few racks, so CDU selection starts at the rack level. Check four factors.
1. GPU platform. Cold plate design determines the required coolant temperature and flow. Lianli's standard GPU cold plate is designed for a 40 °C inlet at 1 L/min. Its GB300 cold plate for the GB300 NVL72 platform supports a 45 °C inlet and uses UQD04 quick connectors.
2. Kilowatts per rack. A single high-density rack can use a dedicated in-rack CDU to handle its heat load. A full row of high-density racks can typically share one in-row CDU.
3. Total IT load. The hall's total liquid-cooled load determines whether it is better served by multiple in-rack units or one or more in-row units, as well as how many units are required for redundancy.
4. Facility water. Use a liquid-to-liquid CDU where a facility water loop is available. Where there is no facility water loop, an air-liquid hybrid CDU rejects heat to room air and requires no chilled-water piping.
Lianli AI Data Center CDU Specifications by Model
| Lianli model | Form factor | Heat exchange capacity | Temperatures | Flow |
| 4U 65 kW / 6U 130 kW in-rack CDU | Liquid-to-liquid, in rack | 65 / 130 kW | Primary 30/40 °C, secondary 40/50 °C | 6 / 12 m³/h |
| 4U 8 kW / 6U 12 kW / 8U 18 kW in-rack CDU | Air-liquid hybrid, in rack | 8 / 12 / 18 kW | Supply/return 40/50 °C | See spec sheet |
| 130 kW air-liquid hybrid in-row CDU | Air-liquid hybrid, in row | 130 kW | Air inlet/outlet 25/40 °C, coolant 40/50 °C | 12 m³/h coolant |
| 500 to 2,000 kW in-row CDU | Liquid-to-liquid, in row | 500 / 800 / 1,000 / 1,500 / 2,000 kW | Primary 30/40 °C, secondary 40/50 °C | 45 to 180 m³/h |
Lianli’s 4U 65 kW in-rack unit measures 482×900×178 mm and weighs 68 kg. The 6U 130 kW in-rack unit measures 482×900×267 mm and weighs 88 kg in operation. A 4U 6 kW in-rack air-liquid hybrid CDU is available for smaller single-rack loads.
Warm-Water Loops and Primary-Side Heat Rejection
Lianli designs its CDUs for warm-water operation. The standard secondary-side temperatures are 40/50 °C, a range suited to free cooling with dry coolers. Lianli also manufactures and supplies cold plates, cabinets, dry coolers and cooling towers, so it can include primary-side and rack-side equipment in one quote. The CDU range is compatible with deionized water, aqueous ethylene glycol solutions and aqueous propylene glycol solutions.
CDU Redundancy, Monitoring and Service
Lianli's in-rack liquid-to-liquid CDU comes standard with N+1 redundant pumps and dual power supplies. A three-year factory warranty covers the pumps, heat exchanger and control electronics. The 500 kW in-row model also uses N+1 pumps. In-row CDUs are available with 2+1, 3+1 and 4+1 redundancy configurations.
The 600 kW in-row CDU includes dew point monitoring with anti-condensation protection, leak detection, undervoltage monitoring, heat exchanger blockage detection, automatic pressure relief, power-off memory, automatic restart when power returns and remote monitoring. The 130 kW air-liquid hybrid unit offers optional communications support for Modbus RTU/TCP, RS485, Ethernet and BMS integration.
Data center products come with a standard three-year warranty. Lianli provides overseas customers with online video guidance for installation and ships spare parts and special tools with the equipment.
Case Study: A 3 MW H200 AI Data Center Project
For an unnamed AI data center project in Xinjiang, Lianli supplied a liquid cooling solution for 128 NVIDIA H200 GPU servers with a total IT load of about 3 MW. The scope included GPU and CPU cold plates, rack distribution manifolds, row-level and room-level CDUs, outdoor dry coolers, piping and a DCIM system. The target delivery timeline was 60 days from design through acceptance.
What to Confirm Before Requesting a CDU Quote
Before requesting a quote from Lianli, confirm the server model and quantity, redundancy requirements (N+1 or 2N), local temperature and humidity, three-phase voltage and frequency, UPS and diesel generator requirements, and project stage and budget range. The minimum order is one unit. Standard payment terms are T/T with a 70% deposit and the remaining 30% due before shipment. Other terms are negotiable. Production and shipment typically take 4 to 8 weeks after signing, with another 2 to 5 weeks for sea freight. Timing depends on the model, quantity and level of customization.
Summary
Lianli's CDU range suits AI infrastructure teams using cold-plate cooling that want a single manufacturer for rack-level and room-level CDUs. The range includes 65 kW and 130 kW in-rack liquid-to-liquid units, 500 to 2,000 kW in-row liquid-to-liquid units and air-liquid hybrid models for rooms without facility water. The in-rack units and 500 to 2,000 kW in-row models use a 40/50 °C secondary loop. Confirm the GPU platform, power per rack, total IT load and facility water availability before choosing a form factor.
Send the server model and redundancy target through the Get a Quote form on lianliwork.com or WhatsApp +86-18002936305.
FAQ
Which CDU size fits a single GB200 or H200 rack?
An in-rack CDU suits a single high-density GPU rack when facility water is available. Lianli rates the heat exchange capacity of its 4U 65 kW and 6U 130 kW in-rack units at primary-side temperatures of 30/40 °C. Calculate the rack's liquid-cooled load, then match it to the rated capacity on the spec sheet.
When does an in-row CDU make more sense than in-rack units?
An in-row CDU is the better choice when an entire row of GPU racks shares one secondary cooling loop. Lianli's in-row liquid-to-liquid CDUs range from 500 kW to 2,000 kW. Calculate the row's total liquid-cooled load and confirm the redundancy requirements before selecting a model.
Can a CDU work without facility chilled water?
An air-liquid hybrid CDU can operate without facility chilled water. Lianli's 130 kW in-row air-liquid hybrid CDU rejects heat directly to room air at design inlet and outlet temperatures of 25/40 °C. It requires neither external chilled water nor a raised floor. Before deployment, confirm that the room's air conditioning can handle the additional heat load.
What certifications and conformity documents does Lianli hold?
Lianli's in-rack CDUs, air-liquid hybrid CDUs, cabinet-based (in-row) CDUs and air-liquid hybrid cabinets have CE and FCC conformity documents, and its 20 ft and 40 ft containers have CE conformity documents. Lianli is certified to ISO 9001:2015 for its quality management system.
What support does Lianli provide after a CDU ships overseas?
Lianli provides overseas CDU customers with remote technical guidance, spare parts supply, project delivery coordination and online video guidance for installation. Each shipment includes spare parts, special tools, a detailed user manual and installation and maintenance manuals.
How long does it take to receive a Lianli CDU?
Lianli completes production and shipment about 4 to 8 weeks after signing, with another 2 to 5 weeks for sea freight. Timing depends on the model, quantity, customization, certification requirements, customs clearance in the destination country and sailing schedules. Custom equipment or full-rack projects may take longer.