Choosing a Liquid-Cooled Server Cabinet for High-Density Racks in 2026: 35 kW to 120 kW

2026年11月19日

Choose a liquid-cooled server cabinet for high-density racks based on the heat load per rack and how the servers are cooled. Lianli's air-liquid hybrid cabinets suit projects transitioning from air cooling to liquid cooling at 35 to 55 kW per rack. For servers already equipped with cold plates and a heat load of about 50 kW per rack, choose Lianli's 48U liquid-cooled cabinet or 48U liquid-cooled door cabinet. For Open Rack V3 projects, the ORV3-44OU rack reserves space for a CDU and liquid cooling pipes. For immersion cooling, Lianli offers server immersion tanks with heat exchange capacities of 40 kW and 120 kW.

Rack Density Bands and Liquid Cooling Methods for Server Cabinets

  • Air-liquid hybrid: Liquid cooling inside the cabinet, combined with air handling for the remaining heat. Suited to rooms transitioning from air cooling.
  • Cold-plate liquid-cooled cabinets: Distribution manifolds and quick connectors supply cold plates on each server. Suited to racks of liquid-cooled GPU or CPU servers.
  • Open Rack V3 with DLC space: A 21-inch frame with space reserved for a CDU and liquid cooling pipes.
  • Immersion tanks: Servers are immersed in cooling oil, and a plate heat exchanger transfers the heat to water.

Air-Liquid Hybrid Server Cabinets: 35 kW and 55 kW

Lianli's 48U air-liquid hybrid cabinet comes in two configurations. Key specifications include:

  • 35 kW and 55 kW cooling capacity
  • 40 to 50 °C supply and return water temperatures, with flow rates of 53 L/min and 83 L/min, respectively
  • deionized water, ethylene glycol solution or propylene glycol solution
  • cabinet dimensions of 600 mm wide, 1,370 mm deep and 2,200 mm high
  • a 380 V, 16 A PDU with 20 outlets, 20 UQD04 male connectors and two distribution manifolds
  • industrial-grade dripless quick-connect couplings

48U Liquid-Cooled Server Cabinets for Cold-Plate Servers

Lianli offers two 48U liquid-cooled cabinets. Both are 19-inch models rated at 50 kW.

  • 48U liquid-cooled cabinet: Rated cooling capacity of 50 kW, a 220 V power supply, 20 UQD04 male connectors, two distribution manifolds and a flow rate of 12 m³/h.
  • 48U liquid-cooled door cabinet: Rated cooling capacity of 50 kW and a flow rate of 12 m³/h.

The 48U liquid-cooled cabinet works with Lianli's cold plates. Its 1,000 W GPU cold plate is designed for a 40 °C inlet temperature and a flow rate of 1 L/min. The GB300 cold plate for the GB300 NVL72 platform requires a 45 °C inlet temperature. It uses UQD04 connectors from the same series as the cabinet manifold connectors.

ORV3 Racks and Server Immersion Tanks

Lianli's ORV3-RACK-44OU follows the Open Rack V3 layout:

  • 44OU of usable height
  • 21-inch internal mounting width and 1,200 mm rack depth
  • native support for ORV3 IT hardware, with an adapter frame for standard 19-inch EIA equipment
  • 48 V power and a DLC-ready design with space for a CDU and liquid cooling pipes
  • shipment fully assembled or in parts

For immersion cooling, Lianli's TANK-12U server immersion tank has a heat exchange capacity of 40 kW, a 220 V, 50 Hz, 50 kW power input and a DN40 pipe connection. It has an 850 mm square footprint and is 1,100 mm high. The TANK-36U has a heat exchange capacity of 120 kW. The 72U server immersion tank has a 200 kW plate heat exchanger and a PLC that displays oil temperature and flow and supports high-temperature alarms and remote monitoring.

Liquid-Cooled Server Cabinet Selection Table

Lianli cabinet

Cooling method

Cooling capacity

Facility condition

Typical applications

Lianli air-liquid hybrid cabinet

Liquid plus air

35 / 55 kW

Supply water at 40 to 50 °C

Rooms converting from air cooling

48U liquid-cooled cabinet

Cold plate via manifolds

50 kW

Liquid loop at 12 m³/h

Racks of cold-plate servers

48U liquid-cooled door cabinet

Liquid cooling

50 kW

Liquid loop at 12 m³/h

Dense 19-inch racks

ORV3-RACK-44OU

DLC-ready, CDU space reserved

Per CDU fitted

48 V Open Rack power

ORV3 builds

TANK-12U / TANK-36U

Immersion

40 / 120 kW

Cooling water supplied to the plate heat exchanger

Immersion-cooled servers

 

Manifolds, CDUs and Ordering

Lianli supplies cabinets, cold plates and CDUs from the same factory, so all three can be included in one quote. Lianli's 65 kW and 130 kW in-rack liquid-to-liquid CDUs are designed for secondary-side temperatures of 40/50 °C.

Before requesting a quote from Lianli, confirm the server model and quantity, redundancy configuration (N+1 or 2N), local temperature and humidity, three-phase voltage and frequency, UPS and diesel generator requirements, and the project stage and budget. The minimum order is one unit. Production and shipment take about 4 to 8 weeks after contract signing, with another 2 to 5 weeks for sea freight. Timing depends on the model, quantity and customization requirements. Data center products come with a three-year warranty.

Summary

For high-density racks, select Lianli's liquid-cooled server cabinet according to rack load and cooling method: 35 kW and 55 kW air-liquid hybrid cabinets for rooms transitioning from air cooling, 50 kW 48U cabinets for cold-plate servers, the ORV3-44OU rack for Open Rack V3 builds, and 40 kW and 120 kW immersion tanks for immersion-cooled servers. Match the server vendor's liquid-cooled load to the cabinet's stated capacity.

Send the server model, rack count and density through the Get a Quote form on lianliwork.com or WhatsApp +86-18002936305.

FAQ

What cooling capacity does a high-density liquid-cooled cabinet need?

The cabinet's cooling capacity must cover the liquid-cooled load per rack specified by the server manufacturer. Lianli offers 35 and 55 kW air-liquid hybrid cabinets, 50 kW 48U cold-plate and door cabinets, and 40 and 120 kW immersion tanks.

Which liquid-cooled cabinet suits a room moving from air cooling?

An air-liquid hybrid cabinet suits rooms transitioning from air cooling. Lianli offers 35 kW and 55 kW models that require supply water at 40 to 50 °C and include a built-in PDU and distribution manifolds.

Does Lianli make ORV3 liquid cooling racks?

Lianli offers the ORV3-RACK-44OU, a 21-inch rack with 44OU of usable height, 48 V power and reserved space for a CDU and liquid cooling pipes. It can also accommodate standard 19-inch equipment with an adapter frame.

What certifications do Lianli liquid-cooled cabinets have?

Lianli's 15 to 65 kW air-liquid hybrid cabinets have CE-MD, RoHS and FCC conformity documents. The documents specify which models are covered. Lianli is certified to ISO 9001:2015 for its quality management system.

What cooling capacity and flow rates do Lianli's air-liquid hybrid cabinets list?

Lianli's air-liquid hybrid cabinets are available in 35 kW and 55 kW models, with upper limits of 38 and 58 kW. They list 12,000 and 16,000 m³/h of airflow and 53 and 83 L/min of water flow. The 48U liquid-cooled door cabinet is a separate 50 kW model rated at 12 m³/h.

What warranty does a Lianli liquid-cooled cabinet carry?

Lianli offers a three-year warranty on data center products, including its liquid-cooled cabinets.