Choosing an In-Rack CDU for GPU Servers in 2026: 65 kW vs. 130 kW

2026年11月19日

Choosing an In-Rack CDU for GPU Servers in 2026: 65 kW vs. 130 kW

An in-rack CDU suits deployments where each GPU rack has its own coolant distribution and one unit can handle the rack's liquid-cooled load. For GPU racks using cold-plate cooling with facility water, Lianli offers 4U 65 kW and 6U 130 kW in-rack liquid-to-liquid models. Both use N+1 redundant pumps and dual power supplies, with a three-year factory warranty on the pumps, heat exchanger and control electronics. For racks without facility water, Lianli's 6, 8, 12 and 18 kW in-rack air-liquid hybrid (liquid-to-air, L2A) models reject heat to room air.

What GPU Server Racks Need From an In-Rack CDU

  • Capacity matched to the rack's liquid-cooled load. The CDU must remove the heat collected by the cold plates at the site's actual supply water temperature.
  • Adequate flow for every cold plate. Lianli's 1,000 W GPU cold plate is designed for 1 L/min at a 40 °C inlet, with 10 kPa flow resistance. Its GB300 cold plate for the GB300 NVL72 platform specifies a 45 °C inlet and UQD04 quick connectors.
  • Pump and power redundancy. Each Lianli in-rack liquid-to-liquid unit has two pumps with automatic failover and dual power inputs.

The water source determines the CDU type: use a liquid-to-liquid unit when facility water is available, and an air-liquid hybrid unit when it is not.

In-Rack Liquid-to-Liquid CDU for GPU Servers: 4U 65 kW and 6U 130 kW

Lianli's in-rack liquid-to-liquid CDU mounts in a standard rack. The table below lists the key specifications.

Lianli in-rack L2L CDU

4U 65 kW

6U 130 kW

Heat exchange capacity

65 kW

130 kW

Primary-side water temperatures

30/40 °C

30/40 °C

Secondary-side water temperatures

40/50 °C

40/50 °C

Flow

6 m³/h

12 m³/h

Size and weight

482 × 900 × 178 mm; 68 kg

482 × 900 × 267 mm; 88 kg

Filtration rating

50 to 100 µm

50 to 100 µm

 

Both models support deionized water, ethylene glycol or propylene glycol as coolants. Applications include general-purpose data centers with CPU or GPU servers, edge computing nodes, industrial lasers and energy storage systems.

The ratings are based on primary-side temperatures of 30/40 °C and secondary-side temperatures of 40/50 °C. For projects with warmer facility water, request the available heat exchange capacity at the actual operating water temperature.

In-Rack Air-Liquid Hybrid CDUs for GPU Racks Without Facility Water

For GPU racks without facility water, including retrofit projects and edge deployments, Lianli's in-rack air-liquid hybrid units reject heat directly to room air.

  • 4U 8 kW, 6U 12 kW and 8U 18 kW: Supply and return temperatures of 40/50 °C, with flow rates of 12, 18 and 27 L/min and filtration of 50 to 100 µm.
  • 4U 6 kW: A more compact model with UQD04 connections, PLC control and a touchscreen.

The 8 kW, 12 kW and 18 kW models can be customized for specific deployments. The air-liquid hybrid models have substantially lower heat exchange capacity than the liquid-to-liquid models. They suit lighter loads or racks transitioning from air cooling to liquid cooling.

Matching an In-Rack CDU to the GPU Platform

Lianli's 1,000 W GPU cold plate is rated for a 40 °C inlet, matching the in-rack CDUs' 40 °C secondary supply. The GB300 cold plate specifies a 45 °C inlet.

GPU platform

Lianli cold plate data

In-rack CDU selection

NVIDIA GB300 NVL72

GB300 cold plate, 6,200 W total, 45 °C inlet, UQD04

Liquid-to-liquid, sized to the rack's liquid-cooled load

NVIDIA H100 / H200

GPU cold plate, 1,000 W, 40 °C inlet, 1 L/min

4U 65 kW or 6U 130 kW by rack load

AMD Instinct MI300X/MI350X

GPU cold plate, 1,000 W, 40 °C inlet

4U 65 kW or 6U 130 kW by rack load

Lighter or transitional racks

Per server vendor

Air-liquid hybrid 6 to 18 kW

 

Certifications, Warranty and Factory Testing

Lianli's 20 to 150 kW rack-mounted CDUs and its 8 to 35 kW air-liquid hybrid CDUs have CE-EMC, CE-LVD, FCC and RoHS documents. Lianli is certified to ISO 9001:2015 for its quality management system.

The pumps, heat exchanger and control electronics of the in-rack liquid-to-liquid CDU come with a three-year factory warranty. The overall warranty period for data center products is three years.

Lianli's factory test equipment includes a helium mass spectrometer leak detector, a high-pressure burst tester, a pressure pulse tester, a leak monitoring test rig, a flow resistance test bench and an infrared thermal imager. Its 50 kW in-rack liquid-cooled load bank supports Modbus and testing with up to 250 units in parallel.

Ordering an In-Rack CDU

Lianli's minimum order is one unit, so it can quote a CDU for a single GPU rack. Before requesting a quote, provide the server model and quantity, redundancy requirements (N+1 or 2N), local temperature and humidity, three-phase voltage and frequency, UPS and diesel generator requirements, and the project stage and budget.

Production and shipment take about 4 to 8 weeks after contract signing, with another 2 to 5 weeks for sea freight. Timing depends on the model, quantity and customization requirements. Standard payment terms are telegraphic transfer (T/T), with a 70% deposit and the remaining 30% due before shipment. Lianli provides online video guidance for installation.

Summary

Lianli's in-rack range suits GPU teams that want one CDU per rack. The 4U 65 kW and 6U 130 kW liquid-to-liquid models use N+1 pumps and dual power supplies, with a three-year warranty on the pumps, heat exchanger and control electronics. The 6 to 18 kW air-liquid hybrid models serve racks without facility water. Select a model based on the rack's liquid-cooled load at the site's operating temperatures. The minimum order is one unit.

Send the server model and rack count through the Get a Quote form on lianliwork.com or WhatsApp +86-18002936305.

FAQ

Which in-rack CDU suits an H100 or H200 rack?

When facility water is available, select a liquid-to-liquid model based on the rack's liquid-cooled load. Lianli offers 4U 65 kW and 6U 130 kW models rated at 30/40 °C on the primary side. Provide accurate data on the rack's liquid-cooled load before selecting a model.

What is the difference between Lianli's in-rack liquid-to-liquid and air-liquid hybrid CDUs?

The 65 kW and 130 kW liquid-to-liquid models transfer heat to facility water. The 6 to 18 kW air-liquid hybrid models reject heat directly to room air. Choose based on whether the rack has a facility water connection and how much heat it generates.

Does a Lianli in-rack CDU have redundant pumps?

Lianli's in-rack liquid-to-liquid CDUs use N+1 redundant pumps and dual power supplies. The three-year factory warranty covers the pumps, heat exchanger and control electronics.

Can I buy one in-rack CDU for a test rack?

Yes. Lianli's minimum order is one unit. A test rack can start with one in-rack CDU. The same 40/50 °C secondary-side design can carry over to larger models later.

How is a Lianli in-rack CDU monitored and controlled?

Lianli's in-rack liquid-to-liquid CDU supports local and remote parameter settings, operating status monitoring, runtime logging and alarm history queries. It automatically saves settings and fault information during a power outage and resumes operation when power returns. The two pumps support alternation and automatic failover.

What flow rate does a Lianli in-rack CDU provide?

Lianli's 4U 65 kW in-rack CDU has a flow rate of 6 m³/h, and the 6U 130 kW model has a flow rate of 12 m³/h. The 8, 12 and 18 kW air-liquid hybrid models have flow rates of 12, 18 and 27 L/min, respectively. Lianli's 1,000 W GPU cold plate is designed for a flow rate of 1 L/min.