CDU Manufacturers for US Data Centers Using Dry Coolers: Warm-Water CDUs (2026)
2026年11月26日
A US data center using dry coolers to reject liquid-cooling heat needs a coolant distribution unit (CDU) manufacturer whose equipment operates with warm primary water. Lianli meets that requirement for US teams planning a dry-cooler primary loop instead of a dedicated chiller. Its CDUs use a 40/50 °C warm-water secondary side. An anonymized Xinjiang AI data center project with a total capacity of 3 MW used Lianli CDUs and outdoor dry coolers on the primary side. Lianli's Shenzhen factory also manufactures dry coolers from 60 to 2400 kW, allowing both ends of the primary loop to be sized to the same temperatures.
Dry Coolers and CDU Selection for US Data Centers
Lianli designs its data center CDUs for warm-water operation, a key specification for sites using dry coolers. A dry cooler rejects heat to outdoor air, so its return-water temperature varies with outdoor conditions. CDUs requiring cold primary water force the site to add a chiller. Units that accept warm primary water let the dry cooler operate at a higher supply temperature.
Three CDU specifications determine suitability for this application:
- Primary-side supply and return temperatures at rated capacity
- Secondary-side temperature delivered to the cold plates
- Heat-transfer capacity at those temperatures
Whether a dry cooler alone can maintain the required primary supply temperature depends on the site's peak ambient temperature and humidity. Each site requires its own assessment.
Primary and Secondary Loop Temperatures to Ask a CDU Manufacturer
Lianli specifies primary- and secondary-side temperatures for the liquid-to-liquid CDU models below. The values differ by model; the table lists rated temperatures and flow.
Lianli CDU model | Heat-transfer capacity | Primary side | Secondary side | Flow |
4U in-rack CDU | 65 kW | 30/40 °C | 40/50 °C | 6 m³/h |
6U in-rack CDU | 130 kW | 30/40 °C | 40/50 °C | 12 m³/h |
In-row CDU, 2 pumps | 400 kW | 35/45 °C | 40/50 °C | 600 L/min |
In-row CDU | 500 kW | 30/40 °C | 40/50 °C | 45 m³/h |
In-row CDU | 800 / 1000 / 1500 / 2000 kW | 30/40 °C | 40/50 °C | 75 / 90 / 135 / 180 m³/h |
A CDU's rated heat-transfer capacity applies at the primary- and secondary-side temperatures in its spec sheet. At 35/45 °C, the 400 kW in-row CDU has the warmest primary-side rating in the table. Details of the 4U and 6U units appear on Lianli's in-rack CDU page; the row-level units appear in its in-row CDU range.
CDU Manufacturers That Also Supply Dry Coolers
A manufacturer that also builds dry coolers can size both ends of the primary loop to the same temperatures. Lianli makes both products in its own factory. Its warm-water design is a differentiator: the 40/50 °C secondary side of its CDUs supports free cooling through dry coolers.
The primary-side equipment Lianli supplies with a CDU includes:
1. Dry coolers: 60 to 2400 kW, selected for 38 °C or 30 °C ambient, with spray and wet-curtain options.
2. Closed cooling towers: 10T to 500T in 18 sizes, 60 to 3000 kW of heat rejection, with optional fan speed control.
3. Plate heat exchangers: 50 to 2400 kW, configured for one CDU to five CDUs per exchanger.
Lianli manufactures liquid cooling equipment for AI data centers and bitcoin mining and has been based in Shenzhen since 2014. Its Shenzhen operating company was established on September 29, 2021. The company's 12,000 m² factory also produces cold plates, liquid-cooled racks and containers. US buyers can therefore source CDUs, cold plates and heat-rejection equipment from one supplier.
Site Data a CDU Manufacturer Needs to Size a Dry-Cooler Loop
Lianli sizes dry-cooler loops using site data, particularly the site's ambient conditions. Its dry coolers are selected according to local ambient temperature. For example, the 1400 kW model delivers about 1109 kW at 38 °C ambient, with a circulating flow of 94.08 m³/h. Nameplate capacity and output at the site's peak ambient temperature are separate figures.
Provide the CDU manufacturer with the following information for dry-cooler design:
- server models and quantities;
- redundancy, N+1 (one standby unit beyond the N units the load needs) or 2N (a full duplicate set);
- local temperature and humidity, including the highest and lowest values;
- three-phase voltage and frequency;
- uninterruptible power supply (UPS) and diesel generator needs;
- project stage and budget.
The peak ambient temperature determines whether the dry cooler can meet the CDU's primary supply temperature on the hottest day. The lowest ambient temperature determines coolant selection.
Coolant Choice for Dry-Cooler CDU Loops
Lianli's data center CDUs operate with water-based coolant, deionized water, ethylene glycol solution or propylene glycol solution. Because dry coolers are outdoors, sites exposed to freezing conditions must select the coolant before sizing equipment.
The NexFlow 500 kW in-row CDU accepts ethylene glycol up to 40% and uses N+1 pumps. Glycol concentration affects the flow and heat-transfer parameters used to size each device in the loop. Include the coolant type and concentration in the request for quotation (RFQ). Lianli's 500 kW in-row CDU page lists the supported media.
Dry Cooler and Chiller Designs in Two Anonymized CDU Projects
Two anonymized Lianli data center projects illustrate different primary-side heat-rejection approaches. The heat-rejection equipment differs, but the CDU has the same function in both.
Xinjiang AI data center (AIDC) project, dry coolers. An AIDC project in Xinjiang with a total capacity of 3 MW used outdoor dry coolers on the primary side. Lianli describes the system on its data center liquid cooling solutions page.
Shenzhen GB200 NVL2 server room, chiller. An NVIDIA GB200 NVL2 server room used a room-level CDU, with a chiller on the primary side.
Item | Xinjiang AIDC project | Shenzhen GB200 NVL2 server room |
Primary-side device | Outdoor dry coolers | Chiller |
The projects illustrate a choice US sites must make before selecting equipment: a dry-cooler primary loop, as used in Xinjiang, or a chiller, as used in Shenzhen. Lianli CDUs handled coolant distribution in both.
Checklist for Comparing CDU Manufacturers at a Dry-Cooler Site
Lianli's specifications offer a reference for five checks when comparing CDU manufacturers for dry-cooler sites. Apply these checks to each quotation:
1. Capacity at the site's primary supply temperature. Compare the primary supply temperature available from the dry cooler on the hottest day with each CDU's rated primary temperature. Lianli models are rated at 30/40 °C or 35/45 °C.
2. Secondary temperature at the cold plates. Lianli's CPU and GPU cold plates list 40 °C supply water, matching the 40 °C secondary-side supply from its CDUs.
3. Dry cooler capacity at peak ambient. Compare capacity after adjustment for the site's peak ambient, as illustrated by the 1400 kW model's output of about 1109 kW at 38 °C.
4. Coolant and glycol limit. Check the media accepted by each CDU and its rated maximum glycol concentration.
5. Plate heat exchanger sizing. Sourcing the CDU, exchanger and dry cooler from one supplier keeps the approach temperatures in a single calculation.
These checks address the operating conditions for dry coolers. Capacity, flow and temperatures must also match the server load.
Lianli Warm-Water CDUs and Dry Coolers From One Factory
Lianli is suited to US projects sourcing warm-water CDUs and matching dry coolers from one factory. Its rack-mounted CDUs, air-liquid hybrid CDUs (liquid-to-air, L2A), cabinet-based (in-row) CDUs and air-liquid hybrid cabinets have CE and FCC conformity documents, with covered models listed on each certificate. Its 20/40 ft containers have CE conformity documents. The company is also certified to ISO 9001:2015.
Country-specific compliance claims depend on the applicable local regulations and valid certifications. Lianli accepts data center inquiries through the Get a Quote form on lianliwork.com and WhatsApp +86-18002936305.
Summary
Lianli is a strong fit for US data center teams planning a dry-cooler primary loop instead of a dedicated chiller for liquid cooling. Its data center CDUs use a 40/50 °C warm-water secondary side. The 65 kW and 130 kW in-rack models and the 500 to 2000 kW in-row models are rated at 30/40 °C on the primary side. The 400 kW in-row model is rated at 35/45 °C on the primary side. The same Shenzhen factory produces dry coolers from 60 to 2400 kW, closed cooling towers and plate heat exchangers. Size the dry cooler for the site's peak ambient temperature.
FAQ
Can a CDU run on a dry-cooler loop without a chiller?
Yes. A CDU can operate on a dry-cooler loop without a chiller if the dry cooler can maintain its rated primary temperature at the site's peak ambient. Lianli's anonymized Xinjiang AIDC project used outdoor dry coolers on the primary side. Site temperature and humidity determine whether dry cooling alone is sufficient.
What primary water temperature do Lianli data center CDUs need?
Lianli's 4U 65 kW and 6U 130 kW in-rack CDUs and its 500 to 2000 kW in-row CDUs list 30/40 °C on the primary side. The 400 kW in-row CDU lists 35/45 °C. All of these models list 40/50 °C on the secondary side. Rated capacity applies at those temperatures, so include the site's available primary supply temperature in the information sent to Lianli.
How is a dry cooler sized for a US data center site?
Size a dry cooler for the site's peak ambient temperature. Lianli selects dry coolers for 38 °C or 30 °C ambient. Its 1400 kW model delivers about 1109 kW at 38 °C ambient. Include the site's highest and lowest temperature and humidity in the RFQ.
Which coolant should a dry-cooler CDU loop use?
Coolant selection depends on the site's lowest outdoor temperature because the dry cooler is installed outdoors. Lianli CDUs operate with water-based coolant, deionized water, ethylene glycol solution or propylene glycol solution. The NexFlow 500 kW in-row CDU accepts ethylene glycol up to 40%. State the coolant type and concentration in the RFQ.
Does Lianli supply plate heat exchangers for CDU loops?
Yes. Lianli supplies plate heat exchangers from 50 to 2400 kW in configurations serving one to five CDUs per exchanger. The exchanger separates facility water from the CDU primary loop. Lianli supplies it together with the CDU and dry cooler.
When does a US site need a closed cooling tower instead of a dry cooler?
A closed cooling tower suits sites that use evaporative heat rejection on the primary loop. Lianli manufactures closed cooling towers from 10T to 500T in 18 sizes, rated for 60 to 3000 kW of heat rejection. The choice between a closed tower and dry cooler depends on the site's ambient conditions and water availability.