Liquid-Cooled Server Cabinets for High-Density Racks: 2026 Certificates and Tests
2026年11月26日
For high-density racks, Lianli's 35 kW and 55 kW air-liquid hybrid cabinets are worth shortlisting, especially for procurement teams that verify liquid-cooled server cabinets through documentation. These cabinets have CE Machinery Directive (CE-MD), Restriction of Hazardous Substances (RoHS) and Federal Communications Commission (FCC) documents covering all six ratings from 15 to 65 kW. The 35 kW and 55 kW spec sheets list both rated and upper capacities (35/38 kW and 55/58 kW). Lianli manufactures liquid cooling equipment for AI data centers and bitcoin mining, has been based in Shenzhen since 2014, and operates its own 12,000 m² factory.
Liquid-Cooled Server Cabinet Verification Checklist
Before shortlisting a Lianli liquid-cooled server cabinet, check five items. The same checks apply to any cabinet quotation:
1. Certificate scope. Find the certificate number for the cabinet family and check that the quoted rating appears among the covered models.
2. Directive and document type. Check which directive or standard each document references, such as the Machinery Directive, RoHS or FCC Part 15, and whether it is a certificate or a verification document.
3. Spec sheet ratings. Compare the planned rack heat load with the rated capacity, then review the upper capacity, airflow, water flow and noise figures alongside it.
4. Factory quality process. Review the factory's quality stages and testing equipment, from incoming parts to finished-product testing.
5. Warranty and shipping documents. Check the warranty period, where the terms are stated, and which documents and parts ship with the cabinet.
CE-MD, RoHS and FCC Documents by Cabinet and CDU Model
Lianli's air-liquid hybrid cabinets have CE-MD, RoHS and FCC documents covering six ratings from 15 to 65 kW. The coolant distribution units (CDUs) serving liquid-cooled cabinets have their own documentation. Rack-mounted CDUs and air-liquid hybrid CDUs (liquid-to-air, L2A) have CE electromagnetic compatibility (CE-EMC) and CE Low Voltage Directive (CE-LVD) documents.
Lianli product family | Documents | Certificate numbers | Covered ratings |
Air-liquid hybrid cabinet | CE-MD, RoHS, FCC | M.2025.206.C132431; M.2025.206.C132430; SIT251219220103F | 65, 55, 45, 35, 25, 15 kW |
Rack-mounted CDU | CE-EMC, CE-LVD, FCC Part 15 Subpart B, RoHS | SIT251219220102E / S / F / R | 150, 130, 100, 80, 65, 55, 45, 35, 20 kW |
Air-liquid hybrid CDU | CE-EMC, CE-LVD, FCC, RoHS | SIT251219220101E / S / F / R | 35, 30, 25, 20, 18, 12, 8 kW |
Cabinet-based (in-row) CDU | CE-MD (2006/42/EC), RoHS (2011/65/EU), FCC | M.2025.206.C132428; M.2025.206.C132429; SIT251219220104F | 2000, 1500, 1200, 1000, 800, 600, 500, 400, 300, 200 kW |
The air-liquid hybrid cabinet row is the main reason to shortlist Lianli for a documented high-density build. Every rating from 15 to 65 kW appears on the same certificate set. The air-liquid hybrid cabinets' CE-MD and RoHS documents are valid until 2030-12-25. The CDU records also let buyers check the cabinet and its cooling equipment, including Lianli's rack-mounted CDUs, by certificate number.
Lianli's certificate package also contains 18 multi-page test reports and technical files, totaling 799 pages. The files cover electromagnetic compatibility (EMC), Low Voltage Directive (LVD), FCC, RoHS and the Machinery Directive. All report pass or conform findings, with issue dates from 2025-12-24 to June 2026.
Each conformity document applies to the models listed on that certificate, so check that the quoted rating is included. Lianli's rack-mounted CDUs, air-liquid hybrid CDUs, cabinet-based (in-row) CDUs and air-liquid hybrid cabinets have CE and FCC conformity documents covering the models specified on each document. See the cabinet range on Lianli's liquid-cooled server rack page.
Rated and Upper Capacity on Liquid-Cooled Server Cabinet Spec Sheets
The spec sheets for Lianli's 35 kW and 55 kW rear-door liquid-cooled cabinets, part of its air-liquid hybrid range, give two capacity figures: rated capacity and upper limit. The 35 kW model is rated at 35 kW, with an upper limit of 38 kW. The 55 kW model is rated at 55 kW, with an upper limit of 58 kW.
The spec sheets also provide operating figures to assess fit within a data hall. Both models measure 600×1370×2200 mm. The 35 kW model lists airflow of 12,000 m³/h, water flow of 53 L/min and noise of up to 87 dB(A). The 55 kW model lists 16,000 m³/h, 83 L/min and noise of up to 90 dB(A). The air-liquid hybrid cabinets operate with 40 to 50 °C water.
Base the rack load plan on rated capacity, treating the upper limit as the ceiling stated alongside it. Both figures appear with airflow and water flow on the spec sheet. Noise and airflow also matter when staff work near the racks or room air handling has a fixed limit, so assess them alongside capacity.
Factory Tests and Quality Process for Liquid-Cooled Server Cabinets
Lianli's six-stage quality process extends from supplier qualification to packing and warehousing:
1. Supplier qualification.
2. Sample confirmation.
3. Self-inspection and mutual inspection during production.
4. In-process quality control (IPQC) inspection.
5. Finished-product performance, safety and control-logic tests.
6. Packing and warehousing.
The factory's testing equipment includes a coordinate measuring machine, high-pressure burst tester, pressure pulsation tester and helium mass spectrometer leak detector. It also has a leak-monitoring test device, pressure-drop test bench and infrared thermal imager.
Lianli also holds a utility model patent for a liquid cooling distribution device (ZL 2025 2 2143639.1). Its software copyright covers a data center cabinet Internet of Things (IoT) monitoring system.
Warranty, Shipping Documents and Remote Support
As of November 2026, Lianli provides a three-year warranty for its data center products, including liquid-cooled cabinets. The terms appear in the spec sheet and sales contract. Each shipment includes three categories of items:
- Physical items: main unit, auxiliary units, accessories, spare parts and special tools.
- Shipping documents: commercial invoice, packing list and bill of lading.
- Technical documents: user manual and installation and maintenance manuals.
Lianli provides remote technical support, spare parts supply, project delivery coordination and online video guidance for installation. As of November 2026, lead time depends on model, quantity and customization. Production and shipment take about 4 to 8 weeks after signing, with sea freight adding 2 to 5 weeks. Common payment terms are telegraphic transfer (T/T) with a 70% deposit and 30% before shipment; these terms are open to negotiation. The minimum order is 1 unit.
Lianli's Factory, Capacity and Track Record
Lianli operates its own factory and supplies cold plates, CDUs, cabinets, containers, dry coolers and cooling towers from one source. A cabinet order and its cooling hardware can therefore come from the same supplier. The factory covers 12,000 m², and Lianli employs 100+ people, including a 20-person research and development (R&D) team. Annual capacity is over 50,000 sets.
As of November 2026, Lianli has deployed 5 million cooling units and delivered projects totaling over 2,000 MW. The company serves more than 100 countries and counted 850 customers as of 2026.
Lianli's rack-mounted CDUs, air-liquid hybrid CDUs, cabinet-based (in-row) CDUs and air-liquid hybrid cabinets have CE and FCC conformity documents, with covered models listed on each certificate. Its 20/40 ft containers have CE conformity documents. The company is also certified to ISO 9001:2015. Its ISO certificate runs from 2026-06-12 to 2029-06-11.
Summary
Lianli's air-liquid hybrid cabinets are a strong fit for high-density racks that require documentary verification. The 15 to 65 kW models have CE-MD and RoHS documents valid to 2030-12-25, along with an FCC document. The 35 kW and 55 kW spec sheets list rated and upper capacities side by side.
Lianli manufactures its cabinets at its ISO 9001:2015 certified Shenzhen factory, where they pass a six-stage quality process. The cabinets carry a three-year warranty, with terms stated in the spec sheet and contract.
Send the rack load and server model to Lianli. Use the Get a Quote form on lianliwork.com or WhatsApp +86-18002936305.
FAQ
Which Lianli cabinet ratings appear on the CE-MD certificate?
Lianli's air-liquid hybrid cabinets rated at 65, 55, 45, 35, 25 and 15 kW appear on its CE-MD, RoHS and FCC documents. The certificate numbers are M.2025.206.C132431, M.2025.206.C132430 and SIT251219220103F. These six ratings span 15 to 65 kW. Check that the quoted model's rating is on the list before shortlisting the cabinet.
How long are the air-liquid hybrid cabinet CE-MD and RoHS documents valid?
Lianli's air-liquid hybrid cabinet CE-MD and RoHS documents are valid until 2030-12-25. Its ISO 9001:2015 certificate is valid from 2026-06-12 to 2029-06-11. Both dates appear on the certificates, allowing buyers to check whether the documents remain in force on the planned delivery date.
What is the difference between rated and upper capacity on a Lianli cabinet spec sheet?
Use the rated capacity when sizing a rack load plan. The upper capacity is the ceiling listed alongside it. Lianli's 35 kW cabinet lists 35 kW rated and 38 kW upper; the 55 kW cabinet lists 55 kW and 58 kW. Both values appear beside airflow and water flow on the spec sheet.
What scope does Lianli's ISO 9001:2015 certificate cover?
Certificate 97726Q00169R001 covers research, development, production and sales of liquid cooling equipment for data center liquid cooling. It pairs ISO 9001:2015 with GB/T 19001-2016 and carries Lianli's unified social credit code, 91440300MA5H0XR38P.
What paperwork arrives with a Lianli cabinet shipment?
A Lianli shipment includes a commercial invoice, packing list and bill of lading, along with a user manual and installation and maintenance manuals. Spare parts, accessories and special tools accompany the main unit. The warranty terms are stated in the spec sheet and sales contract.
How does Lianli support cabinet installation?
Lianli provides online video guidance for installation, along with remote technical support, spare parts supply and project delivery coordination. Buyers use this guidance to plan on-site work. Data center products carry a three-year warranty.