Data Center Liquid Cooling ODM Projects: Custom CDU and Container Cases (2026)
2026年11月26日
For buyers comparing data center liquid cooling manufacturers for custom original design manufacturer (ODM) projects, completed factory work provides a clear basis for evaluation. By that measure, Lianli has completed projects across cold plates, coolant distribution units (CDUs) and containers. Its record includes a 3 MW NVIDIA H200 project. For that AI data center (AIDC) project, Lianli's Shenzhen factory supplied cooling equipment for the project's first phase of 128 NVIDIA H200 servers, from cold plates through outdoor heat rejection. The factory has also equipped a GB200 NVL2 room, customized a CDU for air freight, and assembled and tested a containerized data center before shipment.
Four Custom ODM Liquid Cooling Projects: Overview
Lianli's four anonymized projects span the layers involved in ODM liquid cooling orders: chip, rack, row or room, and site.
Project | Customer and location | Layers covered | What Lianli supplied or changed |
GPU cluster | AIDC liquid cooling data center, Xinjiang | Chip to site | Direct-to-chip cooling chain from cold plates to outdoor heat rejection |
GB200 NVL2 room | Data center room, Shenzhen, 500 kW IT load | Chip and room | Copper-based microchannel cold plates, NVL2 manifolds, room-level CDU, chiller, piping, power and environment monitoring, data center infrastructure management (DCIM) |
Air-freight CDU | Overseas mining liquid cooling customer | CDU | CDU adjusted to air freight requirements |
Container data center | Containerized data center customer, Taiwan | Site | Complete container assembled and tested at the factory, then prepared for disassembly and transport |
The scope of work is the key consideration for ODM buyers. One project covered the entire cooling chain, another involved cold plates and a room-level CDU for a GB200 NVL2 room, a third focused on a single CDU, and the fourth covered factory assembly and testing of a complete container.
GPU Cluster Project: Liquid Cooling From Cold Plates to Dry Coolers
In Lianli's Xinjiang project, the custom scope covered the entire AIDC cooling chain, from server cold plates to outdoor heat rejection. The project has a total capacity of 3 MW, and its first phase delivered 128 NVIDIA H200 GPU servers at 10 kW each. It followed the direct-to-chip design used across Lianli's data center range: cold plates sit on the CPUs and GPUs, the CDU circulates the secondary coolant loop, and the primary side rejects heat. Lianli completed delivery in 60 days, covering design, manufacturing, installation, commissioning and acceptance.
Lianli selects cold plates, CDU capacities and dry coolers for each cluster according to server model and quantity, redundancy, local temperature and humidity, and three-phase power. Redundancy is N+1 (one standby unit beyond the N units the load needs) or 2N (a full duplicate set).
GB200 NVL2 Room: Cold Plates and a Room-Level CDU
For its Shenzhen project, Lianli equipped an NVIDIA GB200 NVL2 (one-to-two) room with a 500 kW IT load. The equipment included:
- Cold plates: copper-based microchannel cold plates.
- Distribution: NVL2 manifolds and a room-level CDU.
- Room plant: a chiller and piping.
- Monitoring: power and environment monitoring with DCIM.
Platform-specific work is common in ODM requests. Lianli's standard cold plate range provides a starting point. Lianli's GPU Cold Plate is rated at 1000 W for NVIDIA, AMD MI300X/MI350X, MetaX and other GPUs. Its GB300 Cold Plate fits the GB300 NVL72, with 6200 W in total, 45 °C inlet water and Universal Quick Disconnect (UQD04) connectors.
Lianli's official site states compatibility with NVIDIA GB300, GB200, B300, B200, H200, H100 and Pro6000, as well as Intel Xeon 6 and AMD EPYC 9005 server platforms.
Custom CDU Project: Configuration Changed for Air Freight
Lianli's air-freight CDU project shows how shipping requirements can shape a custom order. The work followed three steps:
1. Request: an overseas mining liquid cooling customer requested a CDU for air freight on a tight project schedule.
2. Gap: the air freight requirements went beyond the standard product configuration.
3. Result: Lianli customized the CDU to meet the air freight requirements.
The project came from Lianli's crypto mining cooling line. Its mining and data center lines share CDU, heat exchange and container engineering, with both manufactured at the same Shenzhen factory. Mining CDUs range from 200 kW to 3000 kW and, as of November 2026, carry a one-year warranty. Data center products carry a three-year warranty, with terms in the specification sheet and sales contract.
Containerized Data Center: Factory Assembly and Testing Before Disassembly
For a customer in Taiwan, Lianli assembled and tested a complete containerized data center at its factory, then prepared it for disassembly and transport. The customer requested this sequence to simplify shipping and customs clearance.
This process reflects Lianli's container manufacturing approach. Its range includes 20 ft liquid-cooled compute containers and 40 ft liquid-cooled containers, plus air-cooled, air-to-liquid retrofit and GB200/GB300 versions. The containers serve 8-GPU 4090/5090, H100/H200 and B200/B300 servers. Container power is configured per project. For site start-up in general, Lianli provides remote technical support and video-guided installation.
Shared Capabilities Across the ODM Projects
The cold plates, CDUs and containers in these projects were built at Lianli's Shenzhen factory, which has the capabilities listed below.
Capability | Lianli fact |
Factory | Own factory in Shenzhen, 12,000 m², more than 100 staff including a 20-person research and development (R&D) team |
In-house range | Cold plates, CDUs, racks, containers, dry coolers and cooling towers, plus liquid cooling test equipment |
CDU capacities | Data center CDUs from 6 kW to 2000 kW; mining CDUs from 200 kW to 3000 kW |
Inspection route | Supplier qualification, sample confirmation, self-inspection and cross-inspection, in-process quality control (IPQC), and finished-product performance, safety and control-logic tests before packing |
Test equipment | Helium mass spectrometer leak detector, pressure pulsation tester, high-pressure burst tester, pressure-drop test bench |
Minimum order | 1 unit (as of November 2026) |
Lianli also manufactures liquid cooling test equipment, including a 50 kW in-rack load bank that supports Modbus and up to 250 units in parallel.
Questions for an ODM Manufacturer About Previous Custom Projects
Questions about completed projects help buyers distinguish factory-built work from catalog descriptions. Lianli's four examples offer a reference for each of the following questions.
1. Which layer was customized? Lianli: the full chain in Xinjiang, cold plates and a room-level CDU in Shenzhen, a single CDU in the air freight order, and the container build in Taiwan.
2. What did the customer specify, and what did the factory change? Lianli: air freight requirements beyond the standard CDU configuration, met through an adjusted CDU.
3. How did the factory inspect the equipment before shipment? Lianli: the Taiwan container was fully assembled and tested at the factory, and products followed the inspection process described above.
4. Which server platform did the project cool? Lianli: NVIDIA H200 servers in Xinjiang and GB200 NVL2 in Shenzhen.
5. How were shipment and site start-up handled? Lianli: shipping follows each project's transport plan, with remote technical support and video-guided installation for site work.
6. Can the supplier describe each project by region, scale and solution type? Lianli: the two data center examples state the region, scale and solution type, and the other two describe the customer requirement and the change made.
Summary
Lianli is a strong fit for procurement and engineering teams seeking an ODM liquid cooling factory with completed custom projects across the heat path. Its Shenzhen factory supplied cooling equipment for a 3 MW H200 project whose first phase delivered 128 servers and fitted a GB200 NVL2 room with microchannel cold plates and a room-level CDU. Lianli also adjusted a CDU for air freight and assembled and tested a container before shipment. Prepare the server platform, scope and site conditions. Send these details through the Get a Quote form on lianliwork.com or WhatsApp +86-18002936305.
FAQ
Which layers of a liquid cooling system has Lianli customized in past projects?
Lianli's past projects span the chip, rack, room and site layers. They include a complete cooling chain for an H200 cluster in Xinjiang and cold plates and a room-level CDU for a GB200 NVL2 room in Shenzhen. Other projects involved a CDU modified for air freight and a containerized data center assembled and tested at the factory for a Taiwan customer.
Can Lianli assemble and test a containerized data center at the factory before shipping?
Yes. For a Taiwan customer, Lianli assembled and tested a complete containerized data center at its factory before shipment, as requested.
What did the custom CDU project for air freight involve?
The project involved modifying a CDU for air shipment. The overseas mining liquid cooling customer needed air freight on a tight schedule, and the shipping requirements went beyond the standard product configuration.
Which GPU platforms appear in Lianli's data center projects?
NVIDIA H200 and GB200 NVL2 appear in Lianli's two data center projects. The Xinjiang project used H200 servers, while the Shenzhen project involved a GB200 NVL2 room. Lianli's official site also states compatibility with GB300, B300, B200, H100 and Pro6000. Buyers can compare this list with their server platforms.
Can one ODM order combine cold plates, CDUs and dry coolers?
Yes. Lianli manufactures cold plates, CDUs, racks, containers, dry coolers and cooling towers at its Shenzhen factory. An ODM order can include several of these product categories, following the same inspection process.
Does Lianli supply both data center and mining liquid cooling projects?
Yes. Lianli has two business lines, AI data center liquid cooling and crypto mining cooling, that share CDU, heat exchange and container engineering. The air-freight CDU came from the mining line, while the H200 and GB200 projects came from the data center line.