COMPUTEX Taipei 2026: Fully Entering the Era of Liquid Cooling
2026年06月05日
At the Nangang Exhibition Center during COMPUTEX 2026, the silent consensus among enterprise infrastructure architects became deafening: the AI arms race has officially evolved into a full-scale thermodynamic war.
The signs of this paradigm shift are everywhere. Supermicro took center stage with its fully liquid-cooled rack arrays engineered for the NVIDIA Vera Rubin NVL72 platform. Simultaneously, Wiwynn extended its GTC 2026 architecture to Taipei, demonstrating a live coupling of an 800VDC power bus with TE Connectivity’s liquid-cooled vertical busbars. For the first time, the physical blueprint of next-generation AI data centers was showcased not as experimental prototypes, but as a mature, deployable ecosystem.
Yet, behind these newly deployed 600kW clusters lies an even more aggressive roadmap: NVIDIA Rubin Ultra and AMD Instinct MI400 Ultra. These platforms are pushing single-rack power densities toward an unprecedented 1.2MW (Megawatt). To survive this thermal deluge, the industry is witnessing the historical convergence of Microchannel Liquid Cold Plates (MLCP) and Two-Phase Immersion Cooling within a single hybrid architecture, pushing Power Usage Effectiveness (PUE) to the physical boundary of 1.02.
COMPUTEX 2026: The Consolidation of the All-Liquid-Cooled AI Ecosystem
COMPUTEX 2026 has finalized its transformation from a consumer hardware showcase into an enterprise AI infrastructure proving ground. The sheer thermal density of next-gen silicon has rendered traditional air cooling obsolete. The new industry baseline is absolute: 100% liquid-cooled, zero fans, and zero cabling
NVIDIA’s Radical "Three-No" Architecture
The design language of the NVIDIA Vera Rubin Compute Tray is uncompromising: "No Cables, No Hoses, No Fans." By eliminating flexible hoses and internal signal cables, NVIDIA has replaced them with rigid, fluid-solid integrated busbars that handle both coolant distribution and high-density power delivery. Combined with blind-mate Quick Disconnects (QDs), operators can now hot-swappably service a 1.2MW rack just like pulling a traditional hard drive—solving liquid cooling's legacy maintenance bottleneck.
AMD MI400 Series: Breaking the 3kW Per-Chip Barrier
AMD turned heads with the official rollout of its Instinct MI400 Series. With single-chip TDP hovering near the 3kW mark, AMD unveiled its reference Dual-Side Jet-Impingement Microchannel cold plate. By spraying coolant directly onto the precise flip-side coordinates of the HBM4 stacks and the logic die, AMD reduces thermal resistance by 35%, ensuring sustained peak frequencies during massive multimodal LLM training.
Intel Gaudi 4: High-Density, Open-Ecosystem Water Cooling
Intel countered with its Gaudi 4 AI clusters, focusing on aggressive TCO and performance-per-watt. Partnering with major ODMs like GIGABYTE and ASUS, Intel debuted high-density 1U/2U full-water-cooled blade servers. By natively integrating liquid manifolds into the chassis, Gaudi 4 allows hyperscalers to pack more compute nodes into a standard 42U footprint, driving rack density past 400kW without requiring custom infrastructure overhauls.
45°C Warm-Water Cooling: The Counter-Intuitive Standard
In standard Rubin and MI400 configurations, chipmakers are mandating a thermal strategy that sounds completely counter-intuitive: using 45°C (113°F) "warm water" to cool chips generating kilowatts of heat.
| Parameter | Traditional Data Center Liquid Cooling | 2026 AI Flagship Platform (Rubin / MI400 / Gaudi 4) |
|---|---|---|
| Coolant Inlet Temperature | 7°C - 15°C | 45°C - 50°C |
| Primary Cooling Equipment | Chiller operating continuously | Free Cooling / Closed Dry Cooler |
| Thermal Interface Material (TIM) | Conventional Thermal Grease | Ga-In-Sn (Gallium-Indium-Tin) Liquid Metal |
| Cold Plate Flow Channel Design | Millimeter-scale conventional channels | ≤80 μm Gold-Plated / Zinc-Plated Microchannels (MLCP) |
The physics behind this setup relies on the synergy between Microchannel Liquid Cold Plates (MLCP) and Liquid Metal TIMs. Boasting over 10x the thermal conductivity of traditional silicon grease, this setup minimizes the thermal resistance between the die and the fluid.
By operating at a 45°C inlet temperature, data centers can completely bypass energy-hogging mechanical chillers, relying entirely on dry cooling towers even in warmer climates. However, this has skyrocketed the BOM (Bill of Materials) value of the cooling loop. Industry data suggests a single-rack liquid cooling setup now costs between $53,000 and $57,000, with specialized gold- or zinc-plated cold plates accounting for over $30,000 per rack.
Beyond 600kW: The Rise of Hybrid Cooling in Rubin Ultra
While microchannel cold plates are highly effective, single-phase direct-to-chip (D2C) water cooling hits a physical barrier at 100–150 W/cm². Yet, under intense AI training workloads, the localized heat flux of next-gen HBM4 (High Bandwidth Memory) and VRM (Voltage Regulator Modules) can spike to 200–400 W/cm².
To breach the 1.2MW limit, pioneering architectures like Rubin Ultra are deploying a Hybrid Cooling (Cold Plate + Two-Phase Immersion) model:
| System | Temperature Control | Covered Components | Circulating Medium |
|---|---|---|---|
| Rubin Ultra Hybrid Cooling System | Global Control: Microchannel Cold Plate | CPU/GPU Main Chips | Ethylene Glycol Solution |
| Rubin Ultra Hybrid Cooling System | Local Extreme: Two-Phase Immersion | HBM4 / VRM Power | Low-Boiling-Point Electronic Fluorinated Fluid |
This dual-fluid, dual-loop approach offers the best of both worlds: cold plates maintain high density and standard rack serviceability for the main silicon, while localized, hermetically sealed two-phase immersion zones leverage the massive latent heat of vaporization of dielectric fluids to instantaneously eliminate hot spots.
PUE 1.02: Pursuing the Absolute Limits of Thermodynamics
As global regulations regarding data center carbon footprints and energy consumption become increasingly stringent, lowering Power Usage Effectiveness (PUE) is no longer an optional consideration. In contrast to traditional air-cooled facilities—which struggle to push below a PUE of 1.4—and early cold-plate designs that could only reach levels of 1.15, the standard Rubin architecture has successfully reduced PUE to 1.05 by completely eliminating server fans and data center cooling units.
To bridge the final 0.03 gap down to PUE 1.02, two-phase phase-change cooling is mandatory. By submerging extreme components directly in dielectric fluid, the thermal interface material (TIM) layer is entirely removed. The fluid boils directly on the component surface, maximizing the Coefficient of Performance (COP) of the entire refrigeration cycle. PUE 1.02 represents the absolute boundary of what is masterable under the Second Law of Thermodynamics.
Supply Chain Reshuffling: The Ultimate Stress Test
This massive technological shift is aggressively consolidating the global hardware supply chain:
Centralization of Procurement: Chip titans (specifically NVIDIA and AMD) are seizing direct procurement rights for critical cooling components like cold plates, manifolds, and quick disconnects. ODMs (Foxconn, Quanta, Wistron, Inventec) are transitioning from independent system designers into pure rack-level integrators.
The Rise of Tier-1 Liquid Cooling Specialists: Component vendors verified in chipmakers' official ecosystem programs (such as NVIDIA's NPN Tier-1 network) are seeing unprecedented growth. Companies capable of manufacturing zero-leak blind-mate QDs and high-precision Coolant Distribution Units (CDUs) now hold immense bargaining power.
The Material Sciences Boom: Advanced manufacturing techniques, like 3D-printed titanium/aluminum alloy cold plates, are becoming vital for complex multi-chip architectures. Upstream, the demand for low-boiling-point, zero-GWP (Global Warming Potential) eco-friendly fluorinated and silicone fluids is skyrocketing, transforming specialized chemistry into a highly strategic bottleneck.
About Lianli Liquid Cooling:
As a pioneer in AI infrastructure and advanced thermal management technologies, we remain deeply focused on—and have established a comprehensive strategic presence within—the next-generation liquid cooling ecosystem. Lianli manufactures data center cold plates, liquid-cooled server cabinets, CDUs (Coolant Distribution Units), and containerized data centers that are perfectly compatible with server models from NVIDIA, AMD, and Intel—specifically including liquid cooling solutions tailored for NVIDIA’s GB200 and GB300 servers. For access to our white papers on AI data center liquid cooling or to inquire about customized thermal management solutions, please feel free to contact our team of experts.
FAQ
1. Why are AI servers shifting toward "45°C warm-water liquid cooling" in 2026? Can this truly meet their thermal dissipation requirements?
While it may seem counterintuitive, this approach represents a highly efficient choice from the perspective of thermodynamic engineering. Traditional data centers utilize cold water ranging from 7°C to 15°C, necessitating the energy-intensive operation of chiller units. In contrast, next-generation AI platforms—such as NVIDIA Rubin and AMD MI400—have fully embraced Micro-Channel Cold Plate (MLCP) and Liquid Metal (TIM) technologies. By reducing micro-channel flow paths to a scale of ≤80 microns and leveraging the ultra-high thermal conductivity of liquid metal, these systems drastically reduce the thermal resistance between the chip core and the coolant. Consequently, 45°C warm water is sufficient to instantaneously dissipate the heat generated by 3kW-class chips. More importantly, an inlet water temperature of 45°C means that data centers in the vast majority of geographic locations can completely eliminate the need for chillers, relying instead entirely on natural cooling or dry cooling towers; this is the key secret behind data centers being able to push their PUE (Power Usage Effectiveness) ratios toward 1.05—or even as low as 1.02.
2. What is "Cold Plate + Two-Phase Immersion" hybrid cooling technology? What specific engineering pain points does it address?
This represents a forward-looking architectural design developed specifically to address scenarios where single-rack power consumption exceeds 600kW and is trending toward 1.2MW. Traditional "single-phase cold plate liquid cooling" encounters thermal bottlenecks and reaches physical limits regarding high pressure drop when confronted with localized heat flux densities of 200–400 W/cm² (such as those found in HBM4 high-bandwidth memory or VRM power supply modules). Conversely, while "pure immersion liquid cooling" offers extremely high heat exchange efficiency, it necessitates extensive modifications to the overall system architecture and entails relatively complex operation and maintenance procedures. Hybrid Cooling technology offers a perfect fusion of these two approaches: for large surface areas—such as the main CPU and GPU cores—it continues to employ mature, data-center-compatible micro-channel water-cooling plates; however, for extreme localized hotspots—such as HBM4 modules and power supply units—it utilizes small-scale, enclosed two-phase immersion packages that leverage the "warm-water direct boiling phase change" of electronic fluorinated fluids to absorb massive amounts of latent heat. By harnessing the respective strengths of dual-medium and dual-loop systems, this solution perfectly resolves the critical pain points—specifically localized overheating and engineering reliability—associated with megawatt-scale, ultra-high-density computing clusters.
3. How should enterprises across the liquid cooling value chain respond to—and break through—the challenge of computing giants directly dictating supply chains?
As industry titans such as NVIDIA and AMD gradually reclaim procurement control over core components like cold plates, the liquid cooling supply chain is indeed undergoing a drastic reshuffle. ODM manufacturers are shifting their focus from "component-based assembly" toward "full-rack system integration," resulting in a high concentration of market influence among leading players. For companies within this value chain, the key to breaking through lies in the "depth of technological barriers" and the "strategic positioning within new materials."