Server Immersion Tank 12U | Immersion Cooling Server Cooling
Price
Category: power supply
Cumulative views
881
Stock
隐藏域元素占位
- Description
- Specifications
-
- Commodity name: Server Immersion Tank 12U | Immersion Cooling Server Cooling
- Commodity ID: DC-03
Server immersion tank | 12U
Server Immersion Cooling Tank 12U | Liquid Immersion Cooling Server
12U Immersion Liquid Cooling Tank,designed for those who demand extreme density without the roar of traditional fans, this tank is the ultimate solution for AI training, edge computing, and high-frequency trading servers.40kW extreme cooling density ,modular elastic deployment.
By submerging your hardware in a specialized dielectric fluid, eliminate the need for heat sinks and high-RPM fans, achieving a thermal efficiency that air cooling simply cannot touch.
Immersion Cooling Server Tank Parameters
Item Specification Capacity 12U Typical Application Supercomputing Servers Core Advantages Ultra-High Heat Dissipation, Modular Scalability, High-Density Deployment Power Socket / PDU Power Input 220V / 50Hz / 50kW Pipe Diameter DN40, Flange 64 mm Plate Heat Exchanger 40 kW Dimensions (W×D×H) 850 × 850 × 1100 mm Test Ambient Temperature 23 °C Operating Oil Temperature Inlet: 34 °C; Outlet: 41 °C Cooling Capacity 40 kW Oil Filling Volume 300 L Core advantages
1.40kW ultra-high heat dissipation capacity
Single-phase immersion liquid cooling directly contacts the heat source, and the plate heat exchanger efficiently removes heat, easily suppressing the full-load operation of the supercomputing server CPU/GPU cluster, and the heat density is several times higher than that of air cooling.
2.Modular and flexible expansion
The standard 12U tank (850×850×1100mm) supports stacking deployment, and multiple modules are connected in series through a fast interface to meet the elastic expansion requirements from edge nodes to supercomputing clusters.
3.Indoor home-grade silent experience
The fully enclosed immersion design eliminates fan noise, and the operating sound pressure is ≤45dB(A), providing a "zero noise" computer room environment for sensitive scenarios such as scientific research and medical treatment.
4.Intelligent power supply and distribution
Integrated 50KW intelligent PDU (input 220V/50Hz), high-precision monitoring circuit, and RJ45 network management interface to achieve real-time control of current, oil temperature and flow.
Applications:
AI model training and inference clusters
High-performance computing (HPC) environments
Crypto-mining and blockchain data centers
Edge and hyperscale data center deployments
Why Make the Switch?
Traditional air cooling is hitting a physical limit. As TDP (Thermal Design Power) for modern processors exceeds 400W–700W, air simply cannot carry the heat away fast enough.The Bottom Line: Our 12U Immersion Tank reduces energy consumption by up to 40% by eliminating cooling fans and high-power CRAC units, while providing a stable, overclock-friendly environment for your most intensive workloads.Ready to silence your servers and supercharge your density? Contact us for a custom integration quote.
FAQ About Immersion Cooling Server
1. What is server immersion cooling and how does it differ from traditional air cooling?
Server immersion cooling is a thermal management technique where IT hardware is directly submerged in a non-conductive (dielectric) liquid. Unlike traditional air cooling, which relies on fans to blow air over heat sinks, immersion cooling captures 100% of the heat generated by the server components directly into the fluid.
Key Difference: Air is a poor conductor of heat. Liquid is much more efficient, allowing for higher hardware density and the elimination of server fans, which significantly reduces power consumption.
2. What are the primary cost benefits of a liquid immersion cooling server setup?
Transitioning to a liquid immersion cooling server environment offers substantial Return on Investment (ROI) in three main areas:
Energy Efficiency: It can lower the Power Usage Effectiveness (PUE) to near 1.03 by removing the need for energy-intensive air conditioning and server fans.
Hardware Density: Because liquid cools so effectively, you can pack more processing power into a smaller footprint, reducing real estate costs.
Hardware Longevity: Immersion protects servers from dust, vibration, and oxidation, reducing failure rates and maintenance costs.
3. Is the fluid used in a server liquid immersion cooling system safe for electronics?
Yes, the fluid is chemically engineered to be safe. A server liquid immersion cooling system utilizes dielectric fluid, which means it does not conduct electricity.
Safety Profile: These fluids are designed to be non-corrosive, non-toxic, and fire-resistant.
Hardware Safety: Because the fluid is dielectric, it can come into direct contact with electrical components (like CPUs, memory, and capacitors) without causing short circuits or damage.
Return and exchange policy:
1. Domestic customers: Within 7 days of receiving the goods, our quality department confirms that it is a product quality problem;
2. Overseas customers: Within 15 days of receiving the goods, our quality department confirms that it is a product quality problem;
3. The outer packaging is damaged, and abnormalities occurring during transportation are not within the scope of return or exchange (please contact the freight company for claim settlement, and our company can assist with claim settlement);
4. We only provide after-sales service to customers who purchase directly. If you purchase our products from a dealer or a third party, please contact the seller for after-sales service;
5. The product cannot be disassembled after receipt, and cannot be modified or repaired without our permission. Keep the outer packaging and keep the labels intact, otherwise no after-sales service will be provided.