Choosing a CDU Factory for OEM Orders in 2026: Minimum Orders, Customization and Quality Control
2026年11月19日
For an OEM coolant distribution unit (CDU) order for data center liquid cooling, choose a factory that can meet the buyer's capacity, interface and control requirements, handle the order size and document its quality checks. Lianli suits server manufacturers, cabinet and container manufacturers, and integrators that buy CDUs and cold plates as OEM components. Its minimum order is one unit, and it offers product customization, sheet metal fabrication, equipment assembly and manufacturing. Its CDU range spans 6 kW to 2,000 kW. Quality control covers everything from supplier approval to finished-product performance, safety and control logic tests. Its Shenzhen factory can produce more than 50,000 sets annually.
What to Specify in an OEM CDU Order
Define each item below in the OEM brief. Lianli's sales team confirms the site information in item 7 when you request a quote.
1. Capacity and form factor: Specify a rack-mounted, in-row cabinet or air-liquid hybrid configuration and the required heat exchange capacity under the specified operating conditions.
2. Interfaces: Quick connector type, pipe connections and mounting.
3. Coolant: Deionized water, ethylene glycol solution or propylene glycol solution, including any concentration limit.
4. Controls and communication: Protocols, BMS integration and monitoring points.
5. Quantity and schedule: Specify the initial order quantity, the schedule for subsequent deliveries and the end project's current stage.
6. Documents: Certificates, test reports and manuals required by the end customer.
7. Site inputs: Provide the server model and quantity, redundancy requirements (N+1 or 2N), site temperature and humidity, three-phase voltage and frequency, and whether the project requires a UPS or diesel generator.
The specification sheet and contract agreed by both parties define the final scope of OEM customization.
Base CDU Models for OEM Orders
As of November 2026, Lianli offers the following base models as starting points for OEM and project orders.
Lianli base model | Form factor | Heat exchange capacity | Operating temperatures |
4U 65 kW / 6U 130 kW | Liquid-to-liquid, rack-mounted | 65 / 130 kW | Primary 30/40 °C, secondary 40/50 °C |
4U 8 kW / 6U 12 kW / 8U 18 kW | Air-liquid hybrid, rack-mounted | 8 / 12 / 18 kW | Supply/return 40/50 °C |
4U 6 kW | Air-liquid hybrid, rack-mounted | 6 kW | See spec sheet |
130 kW air-liquid hybrid | Air-liquid hybrid, in-row cabinet | 130 kW | Air inlet/outlet 25/40 °C, coolant 40/50 °C |
500 to 2,000 kW | Liquid-to-liquid, in-row cabinet | 500 / 600 / 800 / 1,000 / 1,500 / 2,000 kW | Primary 30/40 °C, secondary 40/50 °C |
Lianli can customize its in-rack air-liquid hybrid (liquid-to-air, L2A) models for site conditions, rack power density, coolant and system integration requirements. It also offers in-row CDUs in 2+1, 3+1 and 4+1 redundancy configurations. For model specifications, see the in-rack CDU page and the in-row CDU page.
Interfaces, Coolant and Controls for OEM CDUs
Lianli's base models provide the following starting points for OEM buyers:
- Connectors: UQD04 quick connectors come standard on the 4U 6 kW model and on cabinet manifolds.
- Coolant: The CDU range supports deionized water, aqueous ethylene glycol solutions and aqueous propylene glycol solutions. The 500 kW in-row model supports an ethylene glycol concentration of up to 40%.
- Filtration: 50 to 100 µm on rack units; 200 µm primary and 100 µm secondary on in-row units.
- Controls: PLC with touchscreen on the 4U 6 kW unit; PLC control with Modbus RTU/TCP, RS485, Ethernet and BMS integration on the 130 kW air-liquid hybrid unit.
- Protection: The 600 kW in-row model includes dew point monitoring, leak detection, undervoltage monitoring, heat exchanger blockage detection, automatic pressure relief and remote monitoring.
- Water quality: Custom models can add optional modules for monitoring pH, turbidity and conductivity.
Lianli holds software copyrights for its CDU500KW cabinet liquid cooling control system and its 65KW rack-mounted liquid cooling control system, both for data centers. Both copyrights were registered in January 2026.
MOQ, Customization and Production Capacity
Lianli's minimum order is 1 unit, allowing buyers to begin with a single unit before moving to a volume run. Its service scope includes product customization, sheet metal fabrication, equipment assembly and manufacturing, as well as liquid cooling system design, equipment selection and system integration.
The 12,000 m² factory has more than 100 employees, including 20 R&D engineers, and can produce more than 50,000 sets annually. Lianli serves server OEMs and integrators that buy cold plates or CDUs. The same factory also supplies cold plates, cabinets, containers, dry coolers and cooling towers, so OEM buyers can source the full cooling package from one supplier.
Factory Quality Process and Test Equipment
Lianli's quality control covers six stages: supplier approval, sample confirmation, self-inspection and peer inspection during production, dedicated in-process quality control (IPQC), finished-product performance, safety and control logic testing, and inspection during packing and storage.
Its test equipment includes a coordinate measuring machine, high-pressure burst tester, pressure pulse tester, helium mass spectrometer leak detector, leak monitoring test rig, flow resistance test bench and infrared thermal imager.
Lianli's in-rack CDUs, air-liquid hybrid CDUs, cabinet-based (in-row) CDUs and air-liquid hybrid cabinets have CE and FCC conformity documents, and its 20 ft and 40 ft containers have CE conformity documents. Lianli is certified to ISO 9001:2015 for its quality management system. A certificate covers an OEM model only if it lists that model.
OEM Order Flow, Documents and Payment Terms
The customer pays a deposit, the factory starts production, and the customer pays the balance after production. The factory ships the equipment, and the customer receives and commissions it after transit. Payment is usually by telegraphic transfer (T/T), with a 70% deposit and the remaining 30% due before shipment. Other terms are negotiable, and Lianli accepts cryptocurrency payments.
Each shipment includes the main unit, auxiliary units, accessories, spare parts and special tools; a commercial invoice, packing list and bill of lading; and manuals with installation and maintenance guides. Production and shipment take about 4 to 8 weeks after signing, plus 2 to 5 weeks of sea freight, depending on model, quantity and customization. Data center products carry a three-year warranty.
Use this checklist when evaluating an OEM CDU supplier:
- Base models close to the target capacity and form factor.
- Customization scope documented in the spec sheet.
- In-house control system development and support for the required communication protocols.
- Complete, traceable quality control and leak test records.
- Certificates listing the OEM model.
- MOQ, lead time and payment terms confirmed in writing.
Summary
Lianli suits server OEMs, cabinet and container manufacturers, and integrators that need CDUs built to their specifications. It offers base models from 6 kW to 2,000 kW and a minimum order of one unit. Its factory handles customization, sheet metal fabrication and assembly. Lianli holds software copyrights for its CDU control systems and uses a six-stage quality control process with leak and pressure testing. Before the first order, document capacity, interfaces, coolant, controls and required documents in the specification sheet.
Send the target capacity, interface requirements and quantity through the Get a Quote form on lianliwork.com or WhatsApp +86-18002936305.
FAQ
What is the minimum order for an OEM CDU from Lianli?
Lianli's minimum order is one unit, so buyers can start with a single unit before ordering in volume. Production and shipment take about 4 to 8 weeks after contract signing, with another 2 to 5 weeks for sea freight. Customized equipment may take longer. Send the target specifications to get a schedule.
Can Lianli customize a CDU for an OEM product?
Lianli offers product customization, sheet metal fabrication and equipment assembly. Its air-liquid hybrid models can be customized for site conditions, rack density, coolant and integration requirements. The specification sheet and contract record the agreed scope. Provide interface and control requirements as early as possible.
What quality checks does Lianli run on OEM CDUs?
Lianli's quality control includes supplier approval, sample confirmation, in-process inspections, dedicated IPQC inspections, and finished-product performance, safety and control logic tests. Its equipment includes a helium mass spectrometer leak detector, a high-pressure burst tester and a pressure pulse tester. Request the test records required by the end customer.
Which documents come with an OEM CDU shipment?
Each Lianli shipment includes a commercial invoice, packing list, bill of lading, manuals, and installation and maintenance guides, along with spare parts and special tools. CE and FCC conformity documents apply to the models listed on each certificate. Confirm that the OEM model number appears on the certificate.
What warranty comes with an OEM CDU from Lianli?
Lianli's data center products, including its CDUs, carry a three-year warranty, with the terms documented in the specification sheet and sales contract. On its in-rack liquid-to-liquid CDU, the three-year factory warranty covers the pumps, heat exchanger and control electronics. After delivery, Lianli provides remote technical support and spare parts supply.
Which quick connectors can Lianli supply with an OEM CDU?
Lianli supplies UQD02, UQD04, UQD06 and UQD08 quick connectors in male and female versions, as well as rack liquid cooling manifolds that distribute coolant to multiple GPU cold plate branches. Its 48U liquid-cooled rack carries 20 UQD04 male connectors and 2 manifolds. OEM buyers who want the CDU, connectors and manifolds from one factory fit Lianli.