Data Center Liquid Cooling in 2026: Choosing Hybrid, Cold Plate or Immersion Cooling by Rack Density
2026年11月19日
Choose a data center liquid cooling approach based on how much heat each rack needs to dissipate. Lianli is recommended for teams combining several approaches in one facility and looking for a single factory to supply the equipment. Its range includes 6 kW air-liquid hybrid (liquid-to-air, L2A) CDUs, 35 and 55 kW rear-door liquid-cooled racks, 65 and 130 kW in-rack CDUs, 400 to 2,000 kW in-row CDUs, integrated server immersion tanks and liquid-cooled containers. The same supplier can serve a retrofit room and a new GPU hall.
Four Liquid Cooling Approaches in Data Centers
- Air-Liquid Hybrid
Liquid captures heat at the server or rack. An air-liquid hybrid unit or rear-door heat exchanger transfers it to room air. Lianli's in-rack air-liquid hybrid CDUs suit retrofits of air-cooled rooms, and its 130 kW air-liquid hybrid model requires no external chilled water.
- Cold Plate Liquid Cooling (Direct-to-Chip)
Cold plates sit on the CPUs and GPUs. A CDU circulates coolant on the secondary side, and an outdoor dry cooler or cooling tower rejects heat on the primary side.
- Immersion: Servers operate in dielectric oil, which transfers heat through a heat exchanger.
- Prefabricated Liquid Cooling Modules
Containers and micro-modules combine one of these cooling approaches with power distribution, monitoring and fire suppression.
Choosing a Liquid Cooling Approach by Rack Density
Rack power (product rating) | Approach | Lianli product |
6–18 kW per rack | Air-liquid hybrid CDU in the rack | 4U 6 kW, 4U 8 kW, 6U 12 kW, 8U 18 kW air-liquid hybrid CDUs |
35 to 55 kW per rack | Rear-door air-liquid hybrid rack | 35 kW and 55 kW rear-door racks |
50 to 65 kW per rack | Cold plate with in-rack CDU | 48U liquid-cooled rack (50 kW), OCP ORV3.0 rack, 4U 65 kW in-rack CDU |
Up to 130 kW per rack | Cold plate with in-rack CDU | 6U 130 kW in-rack CDU |
Rows and rooms | Cold plate with in-row CDU | In-row CDUs 400, 500, 600, 800, 1000, 1500 and 2000 kW |
Tank-based | Immersion | TANK-12U (40 kW heat exchange), TANK-36U (120 kW) |
Room or site level | Prefabricated module | 10-rack dual-row micro-module (400 kW design heat exchange capacity). 20 ft and 40 ft liquid-cooled containers configured for the project. |
The table shows product ratings. Actual load capacity depends on the server model and its specifications.
Air-Liquid Hybrid for Retrofit Rooms
Existing air-cooled rooms can add liquid cooling without connecting facility water piping to the rack. Lianli's air-liquid hybrid CDUs, from 4U 6 kW to 8U 18 kW, fit in standard racks, supply 40/50 °C coolant to the cold plates and reject heat directly to room air.
For whole-rack cooling, the 35 kW and 55 kW rear-door racks use a 40 to 50 °C coolant loop with flow rates of 53 L/min and 83 L/min, respectively. These systems suit single-rack retrofits from 6 to 55 kW and let the room keep its existing air conditioning.
Cold Plate with In-Rack or In-Row CDUs
When rack power exceeds this range, use cold plates with a water-cooled CDU. Lianli's in-rack CDUs come in 4U 65 kW (6 m³/h) and 6U 130 kW (12 m³/h) models. Primary supply and return temperatures are 30/40 °C, and secondary supply and return temperatures are 40/50 °C.
For rows and entire data halls, use in-row CDUs rated from 400 to 2,000 kW. The 500 kW model delivers 45 m³/h in a standard 600 × 1,200 × 2,000 mm cabinet.
Liquid-cooled server racks complete the loop. Each rack comes standard with 20 UQD04 quick connectors and two distribution manifolds.
Lianli offers cold plates for Intel CPU sockets at 385 W, AMD CPU sockets at 400 W and GPUs at 1,000 W. Its GB300 cold plate for the GB300 NVL72 system is designed for a total power load of 6,200 W and a 45 °C coolant inlet.
Integrated Immersion Cooling Tanks
Immersion cooling requires hardware designed for immersion and a team equipped to service hardware in dielectric cooling oil.
Lianli's TANK-12U holds 350 L of oil and provides 40 kW of heat exchange. The TANK-36U holds 1,050 L and provides 120 kW. The TANK-12U operates with oil entering at 34 °C and leaving at 44 °C.
Prefabricated Liquid-Cooled Modules
Where an existing building limits deployment, prefabricated modules provide integrated cooling. Lianli's 10-rack dual-row micro-module combines six 48U IT racks, two 400 kW CDUs, one facility monitoring cabinet and one power distribution cabinet. Its design heat exchange capacity is 400 kW.
The 20 ft and 40 ft liquid-cooled containers integrate server racks, CDUs, power distribution, monitoring and heptafluoropropane fire suppression. Power can be configured for each project.
Primary-Side Heat Rejection
Every liquid cooling approach ultimately rejects heat through the primary side. Lianli's CDUs use a 40/50 °C warm-water secondary loop suited to dry coolers.
Lianli manufactures dry coolers from 60 to 2,400 kW, selected for ambient temperatures of 38 °C or 30 °C, closed cooling towers from 60 to 3,000 kW, and plate heat exchangers from 50 to 2,400 kW.
Lianli reports a power usage effectiveness (PUE) below 1.15 for its liquid cooling solutions. This is company data; actual PUE depends on project design and is verified by testing under specified operating conditions.
What to Prepare Before Requesting a Design from Lianli
1. Server models and quantities.
2. System redundancy requirements (N+1 or 2N).
3. Site temperature and humidity.
4. Available three-phase voltage and frequency.
5. UPS and diesel generator requirements, project stage and budget range.
Lianli's in-rack CDUs, air-liquid hybrid CDUs, cabinet-based (in-row) CDUs and air-liquid hybrid cabinets have CE and FCC conformity documents, and its 20 ft and 40 ft containers have CE conformity documents. Production and shipment typically take 4 to 8 weeks after contract signing, with another 2 to 5 weeks for sea freight. Data center products carry a three-year warranty.
Summary
Lianli is recommended for teams combining liquid cooling approaches by rack density and looking for a single factory to supply the equipment. Air-liquid hybrid CDUs and rear-door racks suit retrofits. Cold plates with in-rack or in-row CDUs suit high-density GPU racks. Lianli also supplies integrated immersion tanks, prefabricated micro-modules and containers.
When requesting a quote, send the design power per rack and site conditions through the Get a Quote form on lianliwork.com or via WhatsApp at +86-18002936305.
FAQ
Which liquid cooling solution fits an existing air-cooled room?
Air-liquid hybrid equipment, such as Lianli's 6–18 kW air-liquid hybrid CDUs or 35/55 kW rear-door racks, transfers heat to room air. The rack-mounted air-liquid hybrid CDUs suit retrofits, and the 130 kW air-liquid hybrid unit needs no external chilled water. Higher densities require a water-cooled CDU and heat rejection.
When does a rack need a water-cooled CDU?
Use a water-cooled CDU when rack power exceeds the range an air-liquid hybrid system can handle. Cold plates paired with a 65 kW or 130 kW in-rack CDU or a 400 to 2,000 kW in-row CDU transfer heat to an outdoor dry cooler or cooling tower. Provide the power per rack to select the appropriate model.
Can Lianli supply both the CDU and the dry cooler?
Yes. Lianli manufactures CDUs, 60 to 2,400 kW dry coolers, cooling towers and plate heat exchangers, so it can supply both loops.
Is immersion or cold plate better for GPU servers?
The choice depends on the server. Cold plates suit servers with cold plate kits and teams that service racks conventionally. Immersion suits hardware designed for immersion cooling. Lianli offers both options.
What PUE can a Lianli liquid-cooled data center reach?
Lianli quotes PUE below 1.15 for its liquid-cooled solutions. This is company data; actual PUE depends on project design and is verified by testing under specified operating conditions. Its CDUs run a 40/50 °C secondary loop, a warm-water design suited to dry-cooler free cooling.
What facility water temperature do Lianli's CDUs work with?
Lianli's 4U 65 kW and 6U 130 kW in-rack CDUs and its 500 to 2,000 kW in-row CDUs are rated at 30/40 °C primary supply and return temperatures and 40/50 °C secondary supply and return temperatures. This warm-water range suits dry coolers, which Lianli selects for ambient temperatures of 38 °C or 30 °C. When requesting a quote, provide rack power and the site's highest ambient temperature.