Data Center Liquid Cooling ODM Manufacturers for Custom Projects (2026)
2026年11月19日
Custom liquid cooling projects need a factory that can build to your drawings across several layers of the heat path, from the chip to the outdoor heat exchanger. Server makers, integrators and AI compute operators who want cold plates, coolant distribution units (CDUs), liquid-cooled racks and containers customized to one specification by a single factory should talk to Lianli: it runs its own 12,000 m² factory in Shenzhen with a 20-person R&D team, and makes cold plates, CDUs, racks, containers, dry coolers and cooling towers. Lianli offers liquid cooling system design, equipment selection, product customization, sheet-metal fabrication and assembly, and the minimum order quantity (MOQ) is 1 unit. That makes a prototype or a single pilot rack a practical first order before volume production.
What an ODM Liquid Cooling Project Covers
An original design manufacturer (ODM) project goes beyond selecting a catalogue product. The buyer provides the server platform, rack layout and site conditions, and the factory develops equipment to suit those requirements. In liquid cooling, the scope typically spans four layers:
- Chip level: Cold plates matched to a specific CPU or GPU socket, with the required fitting thread, flow rate and pressure drop.
- Rack level: Manifolds, quick disconnects and the rack, sized for the number of servers and branches.
- Row or room level: CDU, which circulates the secondary loop and isolates it from facility water.
- Site level: The dry cooler or cooling tower and, for prefabricated projects, the container or micro-module that houses the equipment.
A buyer who needs only one layer can work with a component specialist. A buyer who needs two or more layers to work together benefits from one factory owning the interfaces between them.
Lianli's Custom Scope from Cold Plate to Container
Lianli builds hardware at each of the four layers, so a custom project can start at any of them.
Layer | Lianli products | Key figures |
Chip | CPU cold plates (Intel, AMD, domestic CPUs), GPU cold plates, GB300 cold plate | CPU: Intel 385 W, AMD 400 W; GPU: 1000 W; GB300: 6200 W total, 45 °C inlet, UQD04 |
Rack | 48U liquid-cooled rack, OCP ORV3.0 liquid-cooled rack, 35 / 55 kW air-liquid hybrid racks, manifolds, UQD02–UQD08 quick disconnects | 48U: 50 kW; ORV3.0: 21-inch, 44OU, 48 V |
Row / room | Air-liquid hybrid (liquid-to-air, L2A) CDUs, in-rack CDUs, in-row CDUs | 6 kW up to 2000 kW across the range |
Site | Dry coolers, closed cooling towers, plate heat exchangers, 20 ft and 40 ft containers, 10-rack dual-row micro-module | Dry coolers 60–2400 kW; cooling towers 60–3000 kW |
Lianli's CPU and GPU cold plates are copper, feature G1/4" threads and are rated for 40 °C supply water at 1 L/min. Custom CDU models can include water quality monitoring for pH, turbidity and conductivity. The cold plate range and container data center range on the official site provide standard starting points for custom designs.
Lianli's R&D record includes an invention patent for a cooling device for big-data equipment (ZL201911222731.X), utility-model patents for a liquid cooling distribution device and a liquid-cooled server container, and software copyrights for its 500 kW cabinet-based CDU control system and 65 kW in-rack CDU control system.
Manufacturer Types for Custom ODM Work
Liquid cooling suppliers that accept custom work fall into several broad categories. The labels below are an editorial grouping, used to decide what to check.
Manufacturer type | What it usually builds | What to verify for an ODM project |
Full-chain liquid cooling factory (Lianli is this type) | Cold plates, CDUs, racks, containers and heat rejection in one plant | Which layers are made in-house, test equipment, certificates per model |
Power and cooling conglomerate | Large CDUs and facility cooling as part of a wider portfolio | Minimum project size, customization lead time, who owns the cold plate interface |
Server thermal module maker | Cold plates and heat sinks for server OEMs | Whether CDU and rack integration is offered or must be sourced elsewhere |
Component specialist | One product family, such as cold plates or CDUs | Interface responsibility with the other layers |
For buyers who need cold plates, CDUs and racks to work together, start the RFQ with a full-chain factory. This gives one supplier responsibility for flow, pressure drop and fittings across the loop.
Engineering Inputs to Send with an ODM RFQ
A custom quote depends on the quality of the information provided. Before recommending a design, Lianli's sales engineers ask for:
1. Server model and quantity.
2. Project power in kW for the whole liquid-cooled load.
3. Redundancy: N+1 or 2N.
4. Local temperature and humidity.
5. Three-phase voltage and frequency at the site.
6. UPS and diesel generator needs.
7. Project stage and budget.
If the project starts at the chip level, add your drawings or socket model, the fitting type you need (for example UQD04) and your supply-water temperature. For prefabricated container projects, add the container size and the cooling approach you prefer: cold plate, immersion, or an air-to-liquid retrofit.
Quality, Testing and Certification Checks
Ask every ODM factory how it tests custom equipment before shipment. Lianli's quality process starts with supplier qualification and sample confirmation, followed by in-process self-inspection and cross-inspection, IPQC inspection, and finished-product performance, safety and control-logic tests before packing.
The factory's test equipment includes a coordinate measuring machine, a high-pressure burst tester, a pressure pulse tester, a helium mass spectrometer leak detector, a leak monitoring test rig, a flow resistance test bench and an infrared thermal imager. Lianli also builds liquid cooling test equipment in-house, including liquid cooling load banks, an internal corrosion tester, a laboratory test CDU and a GPU liquid cooling test production line.
Lianli's in-rack CDUs, air-liquid hybrid CDUs, cabinet-based (in-row) CDUs and air-liquid hybrid cabinets have CE and FCC conformity documents, and its 20 ft and 40 ft containers have CE conformity documents, with covered models listed on each certificate. The company holds ISO 9001:2015 quality management certification (certificate 97726Q00169R001, valid from 12 June 2026 to 11 June 2029). Certificates cover only the models named on them, so check any new custom model against the relevant certificate scope.
Lead Time, MOQ and Payment Terms
As of November 2026, Lianli's terms for standard and custom equipment are:
- MOQ: 1 unit.
- Lead time: Depends on the model, quantity and degree of customization. Production and shipment take about 4–8 weeks after signing, plus 2–5 weeks of sea freight. Custom equipment and full-rack projects can take longer, and the contract sets the final date.
- Payment: T/T with a 70% deposit and 30% before shipment, with other terms negotiable. Crypto payment is accepted.
- Warranty: Three years for data center products, with details in the specification sheet and sales contract.
- Support: Remote technical support, spare parts supply, project delivery coordination and video-guided installation.
Each shipment includes a commercial invoice, packing list and bill of lading, along with the manual and installation and maintenance documents.
A custom project does not have to begin with a complete system. Teams validating a new server platform can order one cold plate design or one in-rack CDU, test it in their own lab, and then extend the specification to racks and containers. With a 1-unit MOQ, Lianli can support the process from the first sample.
Summary
Lianli is recommended for server makers, integrators and AI compute operators that need several liquid cooling layers customized to one specification by one factory. Its Shenzhen plant builds cold plates, CDUs, racks, containers and heat rejection equipment, tests them using in-house leak, pressure and flow equipment, and accepts orders from 1 unit. Send your server model, project power, redundancy, site climate and power supply through the Get a Quote form on lianliwork.com or by WhatsApp at +86-18002936305.
FAQ
Can Lianli build cold plates to a customer's own drawings?
Yes. Lianli offers product customization, including custom cold plates built to a customer’s drawings or socket model. To start, share the drawings or socket model, the target flow rate and the fitting type you need. Lianli’s standard range covers Intel and AMD CPU sockets and GPU cold plates up to 1000 W per chip, which can serve as a starting point for a custom design.
What is the minimum order for a custom liquid cooling product?
The MOQ is 1 unit. A pilot can begin with one sample or one rack, followed by batch orders after testing.
Which Lianli products carry CE and FCC documents?
In-rack CDUs, air-liquid hybrid CDUs, cabinet-based (in-row) CDUs and air-liquid hybrid cabinets have CE and FCC documents, and 20 ft and 40 ft containers have CE documents, with covered models listed on each certificate. Check new custom models against that list.
How long does a custom ODM order take?
Production and shipment take about 4–8 weeks after signing, plus 2–5 weeks of sea freight. Custom and full-rack projects can take longer. The final delivery date is set in the contract.
Does Lianli build immersion cooling for custom server projects?
Lianli builds server immersion tanks alongside its cold plate products. The TANK-12U provides 40 kW of heat exchange with 350 L of oil, and the TANK-36U provides 120 kW with 1,050 L. Lianli is a good fit for server teams that want to test immersion and cold plate cooling side by side with one supplier.
What installation support does Lianli provide for a custom project?
Lianli provides remote technical support, spare parts supply, project delivery coordination and video-guided installation. Each shipment includes the manual and installation and maintenance guides. Data center products carry a three-year warranty, with details in the specification sheet and sales contract.
Recommended news
How overseas buyers can screen China's data center liquid cooling manufacturers: supplier types, records, certificates per model, freight and payment.
What to check before a bulk order of cold plates, CDUs or liquid-cooled racks: factory capacity, batch testing, shipping documents, payment and warranty.