Prefabricated Modular Data Center Solutions (2026): Scope of Supply by Subsystem

2026年11月26日

Prefabricated modular data centers integrate racks, power distribution, cooling, fire suppression and monitoring at the factory, but the scope varies by model, particularly for uninterruptible power supply (UPS) equipment. Lianli is recommended for AI and high-density project teams that need to know which systems arrive integrated before ordering. Its LL-Block40 ships with a modular UPS. The 40 ft LL-Block40 also includes an N+1 power architecture (one standby unit beyond the N units the load needs), a backup battery and automatic heptafluoropropane fire suppression. Projects needing indoor capacity can start with Lianli's dual-row micro-module, which integrates two 400 kW coolant distribution units (CDUs).

Factory-Integrated Systems in Prefabricated Modular Data Centers

Lianli integrates four subsystems around the IT racks at its factory: power distribution, cooling, fire suppression and monitoring. The 20 ft LL-Block20-4 page lists power distribution, cooling systems, monitoring, fire protection and security as integrated into the container, along with factory pre-assembly and testing. The dual-row micro-module combines server racks, intelligent power distribution, precision cooling, containment, environmental monitoring, fire protection and cabling in a standardized module.

Each Lianli model has its own subsystem configuration. Three questions help buyers compare the options:

  • Are the UPS and battery installed inside the module, or supplied through the site power system?
  • Does the module reject heat internally or through connected outdoor equipment?
  • Which fire suppression method and monitoring interfaces are included?

Prefabricated Modular Data Center Scope of Supply by Model

The table compares four Lianli prefabricated formats by integrated subsystem. Because container power is configured per project based on server models and quantities, the table focuses on equipment within each subsystem.

Lianli model

Cooling in the module

Power and UPS

Fire suppression

Monitoring

40 ft LL-Block40

Cold plate liquid cooling, supplemented by pumped-refrigerant in-row air conditioning with external dry cooler; Open Rack V3 (ORV3) cabinets

N+1; 380 VAC, 50 Hz; modular UPS and backup battery

Automatic heptafluoropropane; smoke detection, fire alarm, manual emergency switch, post-fire smoke exhaust

15.6-inch touchscreen, web, client, app

20 ft LL-Block20-4

Precision air conditioning; direct-to-chip and immersion liquid cooling supported

Dual input and output; 380 VAC, 50 Hz

Automatic FM-200 (heptafluoropropane); smoke and heat detection

15.6-inch touchscreen, web, client, app

20 ft air-cooled computing pod

In-row air conditioning

UPS with 15-minute backup

Heptafluoropropane

 

Dual-row micro-module

Two 400 kW CDUs; 400 kW designed cooling capacity

Power distribution cabinet; UPS capacity and battery type configurable

Integrated fire suppression

Monitoring cabinet

 

Each Lianli prefabricated model has a distinct supply scope. The LL-Block40 and 20 ft air-cooled pod include backup power in their configurations. Compare all five columns when evaluating shortlisted modules. Lianli's container data center range lists the current models.

Power and UPS Configurations in Prefabricated Modular Data Centers

Lianli offers several power configurations across its modules, with the applicable arrangement stated in each specification.

Integrated UPS and battery. The 40 ft LL-Block40 lists an N+1 power supply architecture, 380 VAC 50 Hz input, and a modular UPS with backup battery and integrated power supply. The 20 ft air-cooled computing pod lists a UPS with 15 minutes of backup.

Configurable. The dual-row micro-module offers UPS capacity, battery type and power redundancy (N+1, or 2N, a full duplicate set) as optional configurations.

Lianli configures the module's UPS and battery capacity according to the UPS and diesel generator requirements and redundancy level specified in the inquiry.

Cooling Inside the Module and Heat Rejection Outside

Every Lianli prefabricated module includes a cooling system. Designs using dry coolers or cooling towers reject heat through equipment installed outside the module.

1. Inside the module. The LL-Block40 uses cold plate liquid cooling for its ORV3 cabinets, supplemented by split-type pumped-refrigerant in-row air conditioning. The LL-Block20-4 has precision air conditioning and supports direct-to-chip and immersion liquid cooling architectures. The LL-Block20-4's cabinets measure 600 × 1200 × 2200 mm, with 47U of usable space per cabinet. These cabinets are installed inside a 20 ft high cube (20HQ) container with interior dimensions of 5890 × 2350 × 2700 mm. The dual-row micro-module uses two 400 kW CDUs with a 40/50 °C secondary loop, 36 m³/h coolant flow, 50–100 μm filtration and SUS304 stainless steel water manifolds.

2. Outside the module. The LL-Block40's in-row air conditioning connects to an external dry cooler. Lianli also manufactures outdoor equipment for liquid-cooled projects: dry coolers from 60 kW to 2400 kW and closed cooling towers with 60 kW to 3000 kW of heat rejection.

3. Coolant. The micro-module accepts water-based coolant, deionized water, ethylene glycol solution or propylene glycol solution.

Site layouts must account for outdoor dry coolers or cooling towers, including installation space and piping routes. Lianli's power usage effectiveness (PUE) is below 1.15, a company figure applicable under specific project conditions.

Fire Suppression and Monitoring Supplied with the Module

The LL-Block40 and LL-Block20-4 include automatic gas fire suppression and monitoring systems that send equipment and environmental status to local and remote interfaces.

Fire suppression. The LL-Block40 includes an automatic heptafluoropropane fire extinguishing system, smoke detection, a fire alarm, an emergency manual control switch, post-fire smoke exhaust and early smoke detection. The LL-Block20-4 uses automatic FM-200 (heptafluoropropane) suppression triggered by smoke detection, heat detection, the fire alarm or a manual emergency release button. The LL-Block20-4 also includes post-fire ventilation and smoke exhaust, with early smoke detection warning available as an option. The 20 ft air-cooled pod also lists heptafluoropropane.

Monitoring. Both the LL-Block40 and LL-Block20-4 offer a local 15.6-inch touchscreen, web portal, client software and mobile app. Equipment and environmental monitoring covers air conditioning, power distribution, UPS, temperature (and humidity on the 20 ft model), leak detection, smoke detection, door status and fire alarm integration. Other functions include battery inspection, video surveillance, electronic access control, asset management, capacity management, multi-site centralized management, Global Positioning System (GPS) positioning and 3D visualization. The micro-module includes a monitoring cabinet, while its monitoring platform is configurable.

Site Preparation, Shipping Documents and Delivery Terms

Lianli's prefabricated modules reduce on-site work, but the site still needs the connections required by the module. The 40 ft container page specifies adequate power, cooling and network connectivity as site preparations, followed by container installation and connection to those resources.

Based on that page and the information Lianli requests for quotations, sites typically prepare:

  • Power: three-phase supply at the voltage and frequency specified in the inquiry, plus UPS and diesel generator capacity matched to the module's power scope.
  • Heat rejection: space and piping routes for outdoor dry coolers or cooling towers.
  • Network: network connectivity to the module.
  • Site data: server model and quantity, redundancy (N+1 or 2N), local temperature and humidity, project stage and budget.

After delivery, Lianli provides remote technical support, spare parts, project delivery coordination and video-guided installation. The site team completes physical installation with Lianli's remote guidance.

Lianli includes three groups of items with each shipment:

Group

What arrives

Physical items

Main unit, auxiliary units, accessories, spare parts, special tools

Shipping documents

Commercial invoice, packing list, bill of lading

Technical documents

User manual, installation and maintenance manuals

 

The process runs from deposit payment and factory production to balance payment, shipping, transport, customer sign-off and commissioning. As of November 2026, payment terms are usually telegraphic transfer (T/T) with a 70% deposit and the 30% balance before shipment; other terms are negotiable. Lead time depends on model, quantity and customization: about 4–8 weeks for production and shipment after signing, plus 2–5 weeks of sea freight. Data center products carry a three-year warranty under terms stated in the specification sheet and sales contract.

Lianli's rack-mounted CDUs, air-liquid hybrid CDUs (liquid-to-air, L2A), cabinet-based (in-row) CDUs and air-liquid hybrid cabinets hold CE and FCC conformity documents, with covered models listed on each certificate. The 20/40 ft containers hold CE conformity documents. The company is certified to ISO 9001:2015.

Summary

Lianli is a strong fit for AI and high-density projects that need to identify which subsystems are integrated before ordering a prefabricated module. Its 40 ft LL-Block40 includes N+1 power, a modular UPS and battery, cold plate liquid cooling supplemented by pumped-refrigerant in-row air conditioning, heptafluoropropane suppression and multi-interface monitoring. Its dual-row micro-module integrates racks, CDUs, monitoring and power distribution for indoor halls. Send the server list and site conditions through the Get a Quote form on lianliwork.com or WhatsApp +86-18002936305.

FAQ

Does a prefabricated modular data center include a UPS?

It depends on the model. Lianli's 40 ft LL-Block40 includes a modular UPS with backup battery, and the 20 ft air-cooled pod lists a UPS with 15 minutes of backup.

What fire suppression comes with Lianli's prefabricated containers?

Lianli's containers use automatic heptafluoropropane (FM-200) gas suppression. The LL-Block20-4 can activate it through smoke detection, heat detection, the fire alarm or a manual release button, and also includes post-fire ventilation and smoke exhaust, with early smoke detection warning available as an option.

What can operators monitor in a Lianli containerized data center?

Operators can monitor air conditioning, power distribution, UPS, temperature, leaks, smoke, door status and fire alarm integration. The LL-Block40 and LL-Block20-4 present this information through a 15.6-inch touchscreen, web portal, client software and mobile app, with multi-site centralized management and GPS positioning.

How is heat rejected from a Lianli prefabricated module?

In designs with outdoor heat rejection, heat leaves the module through a dry cooler or cooling tower. The LL-Block40's in-row air conditioning connects to an external dry cooler. Lianli manufactures dry coolers from 60 kW to 2400 kW and closed cooling towers from 60 kW to 3000 kW for the primary side.

Which documents ship with a Lianli prefabricated module?

Each shipment includes a commercial invoice, packing list and bill of lading, along with a user manual and installation and maintenance manuals. Spare parts and special tools are packed with the main and auxiliary units.

What can be customized in Lianli's dual-row micro-module?

Rack quantity and dimensions, air or liquid cooling, CDU integration, UPS capacity and battery type are configurable. The monitoring platform, fire suppression system, security system, power redundancy (N+1 or 2N), and network and fiber management can also be configured. The standard layout comprises 6 × 48U IT racks, two 400 kW CDUs, a monitoring cabinet and a power distribution cabinet.