8KW/12KW/18KW In-Rack Liquid-to-Air CDU | Data Center & Server Liquid Cooling Systems
Price
Category: power supply
Cumulative views
1000
Stock
隐藏域元素占位
- Description
- Specifications
-
- Commodity name: 8KW/12KW/18KW In-Rack Liquid-to-Air CDU | Data Center & Server Liquid Cooling Systems
- Commodity ID: DC-06
In Rack Air-To-Liquid CDU | 8KW/12KW/18KW
In-Rack CDU for Ultra-High Performance and Low PUE Operation
The In-Rack Liquid-to-Air Coolant Distribution Unit (CDU) series pushes rack-level thermal performance beyond conventional limits with a disruptive dual-mode cooling architecture. By dynamically adjusting the balance between air cooling and liquid cooling, the system delivers a maximum heat dissipation density of up to 12 kW (3 kW per 1U) within a compact 4U footprint—several times the capacity of traditional air-cooled solutions.
Designed for next-generation liquid cooling data center and liquid cooled server deployments, the CDU enables ultra-precise temperature regulation with ±0.5 °C control accuracy. This rapid thermal response suppresses GPU thermal runaway within seconds, significantly improving system stability while reducing overall PUE to as low as 1.15. Inlet and outlet water temperatures are maintained at an efficient 40–50 °C, allowing seamless integration with warm-water cooling loops and improving total energy utilization.
Customers can save 33% of cabinet space and provide a full-scenario energy efficiency revolution from edge computing to supercomputing clusters.

In-Rack Air-To-Liquid CDU Specification
Product Name
4U8KW In-Rack CDU
6U12KW In-Rack CDU
8U18KW In-Rack CDU
Application Scenario
General data center/IDC room/industrial laser/energy storage system
Heat exchange
8KW
12KW
18KW
Inlet and outlet water temperature
40/50℃
Primary side flow
1.2m3 / H
1.5m3 / H
2.1m3 / H
Secondary side liquid type
Deionized water / Ethylene glycol/ Propylene glycol
Size
482*900*178MM
482*900*267MM
482*900*365MM
Filtration accuracy
50~100µm
FAQ:
What is the difference between Liquid-to-Liquid and Liquid-to-Air CDUs?
Liquid-to-liquid CDUs transfer heat to the facility's chilled water circulation system, offering the highest efficiency and making them ideal for high-density environments. In contrast, liquid-to-air CDUs directly release heat into the indoor air, making them suitable for facilities without a dedicated chilled water system.
2.How does a CDU improve data center PUE and efficiency?
A: A CDU improves data center efficiency by providing targeted liquid cooling, which lowers the Power Usage Effectiveness (PUE). By enabling the use of warmer facility water, CDUs reduce the need for energy-intensive chillers and increase the opportunities for free cooling, saving both energy and operational costs.
3.What is the role of a CDU in liquid cooling?
The Coolant Distribution Unit (CDU) acts as the critical interface between the facility’s chilled water and IT equipment. It separates loops, regulates coolant temperature above the dew point to prevent condensation, and ensures precise flow control, making liquid cooling safe and efficient.
Return And Exchange Policy:
1. Domestic customers: Within 7 days of receiving the goods, our quality department confirms that it is a product quality problem;
2. Overseas customers: Within 15 days of receiving the goods, our quality department confirms that it is a product quality problem;
3. The outer packaging is damaged, and abnormalities occurring during transportation are not within the scope of return or exchange (please contact the freight company for claim settlement, and our company can assist with claim settlement);
4. We only provide after-sales service to customers who purchase directly. If you purchase our products from a dealer or a third party, please contact the seller for after-sales service;
5. The product cannot be disassembled after receipt, and cannot be modified or repaired without our permission. Keep the outer packaging and keep the labels intact, otherwise no after-sales service will be provided.
Recommend for you
20-Units Water-Cooled Cabinet | Whatsminer M53/M63/M73 Hyd Series
$
~
$
Lianli crypto immersion cooling | immersion mining system | asic immersion cooling kit
$
~
$
Lianli lmmersion Oil Cooling Tank | Immersion Mining | CryptoMining Immersion Cooling
$
~
$
Crypto Immersion Cooling System For Home Mining | Heating Can accommodate 3 miner
$
~
$