Air-to-Liquid Cooling Retrofit for a Shenzhen Listed Company's Data Center
This project involves retrofitting the existing 16 AI computing servers at a Shenzhen-based listed company's data center, upgrading them from traditional air cooling to a high-efficiency cold-plate liquid cooling system. Classified as a Tier 1 project with a delivery timeline of just 15 days, it aims to rapidly and reliably enhance computing density and energy efficiency to meet the demands of high-load AI workloads.

1. Project Challenges and Core Requirements Analysis
Based on the project background, this retrofit faces three core challenges:
High-Density Cooling Bottleneck: AI computing servers have high power consumption; traditional air cooling struggles to meet their escalating thermal management needs, creating a bottleneck that limits increases in computing power.
Pressure for Rapid Delivery: The 15-day project timeline necessitates a highly modular and standardized retrofit solution capable of rapid deployment, thereby minimizing disruption to ongoing operations.
Adaptation to Existing Data Centers: The retrofit must be executed within the client's current air-cooled data center environment; the solution requires excellent compatibility and must enable the seamless coexistence and synergy of air-cooling and liquid-cooling systems.
2. Lianli Cold-Plate Liquid Cooling Retrofit Solution
Leveraging its mature, full-stack liquid cooling technology, Lianli Technology offers a one-stop, prefabricated, in-situ retrofit solution designed to precisely address the aforementioned challenges.
Core Retrofit Approach
Server-Side Retrofit: Utilizing Lianli Technology’s proprietary, customized cold-plate components, the solution performs an "in-situ retrofit" on existing air-cooled servers. Liquid cooling modules are installed on key heat-generating components—such as CPUs and GPUs—without replacing the server chassis itself. This method effectively lowers core server temperatures and reduces the server's own power consumption by approximately 20%.
Coolant Distribution and Control: Deployment of a rack-mounted Coolant Distribution Unit (CDU)—such as Lianli Technology’s 8kW rack-mounted air-liquid CDU. This unit drives coolant circulation between the server cold plates and the outdoor cooling source, enabling precise temperature control and flow distribution. It also supports a hybrid air-liquid mode, fully utilizing existing air-cooling infrastructure.
Outdoor Cooling Source and Piping Connections: The system connects to an outdoor dry cooler or an integrated cooling station, utilizing natural cooling sources or high-efficiency mechanical refrigeration to provide a continuous cooling supply to the entire liquid cooling system. All prefabricated piping employs high-standard welding and sealing processes to ensure long-term, stable system operation.
Core Solution Advantages:
| Key Advantage | Technical Highlights | Customer Benefits |
|---|---|---|
| Fast Delivery | Standardized CDUs, prefabricated piping, and modular architecture enable rapid installation and commissioning. | Complete liquid cooling deployment in as little as 15 days. |
| High Energy Efficiency | Cold plate liquid cooling removes heat directly from CPUs and GPUs, achieving PUE values below 1.15. | Reduces energy consumption by over 40% and lowers operational costs. |
| Mission-Critical Reliability | Redundant pumps, intelligent monitoring systems, and multiple safety protection mechanisms ensure 24/7 operation. | Minimizes downtime risks and guarantees business continuity. |
| Broad Platform Compatibility | Supports NVIDIA GB200, B200, H200, AMD, Intel, and other high-density computing platforms. | Maximizes existing infrastructure utilization and reduces upgrade costs. |
| Intelligent Operations & Maintenance | Real-time monitoring of temperature, flow rate, pressure, and power consumption with remote management capabilities. | Improves operational visibility while reducing maintenance workload. |
| Global Delivery Capability | End-to-end services covering design, manufacturing, installation, commissioning, and after-sales support worldwide. | Accelerates project execution and reduces deployment risks for international projects. |
3. Implementation Plan and Expected Benefits
Implementation Plan (15 Days)
Days 1–5 (Survey & Design): Conduct on-site surveys; finalize detailed piping designs; prepare for the production of core components such as CDUs and cold plates.
Days 6–10 (On-site Retrofitting): Install server cold plates; deploy CDUs and indoor piping; simultaneously position the outdoor cooling source.
Days 11–13 (Integrated Commissioning & Testing): Perform system fluid filling, air purging, and pressure testing; conduct full-system integrated commissioning and optimization.
Days 14–15 (Acceptance & Handover): Conduct performance acceptance to ensure key metrics—such as PUE and heat dissipation capacity—meet standards; complete project handover and O&M training.

Expected Benefits
Significant Energy Efficiency Improvement: Projected reduction of PUE from over 1.6 (pre-retrofit) to below 1.15, achieving substantial energy savings and emission reductions.
Increased Computing Density: Single racks can support higher-power IT equipment, providing headroom for future computing capacity expansion.
Reduced Operating Costs: Simultaneous reduction in server power consumption and cooling system energy usage; TCO (Total Cost of Ownership) advantages expected to become apparent within one year.
Improved Operating Environment: Effectively reduces server room noise; enhances equipment operational stability and lifespan.
Lianli has provided a mature, reliable, and highly efficient solution for this data center retrofit project—converting air cooling systems to liquid cooling. Leveraging a modular design, rapid delivery capabilities, exceptional energy efficiency, and extensive global deployment experience, the solution enables the safe and stable execution of critical data center upgrades within a very tight timeframe, delivering significant economic and environmental benefits to the client.
Please contact the Lianli liquid cooling technical team to obtain a detailed implementation plan tailored to your specific project.
Previous page
Next page
Related Recommendations
Delivered a computing cluster comprising 128 NVIDIA H200 servers featuring cold-plate liquid cooling within 60 days.
The NVIDIA GB200 NVL2 ultra-high-density compute node utilizes cold-plate liquid cooling technology, is designed to T2 standards, and offers rapid delivery within seven days.
A Shenzhen-listed company completed the cold-plate liquid cooling retrofit for 16 AI servers in 15 days, reducing the PUE to below 1.15.
100MW liquid-cooled blockchain mining project in Kazakhstan, compatible with WhatsMiner M63S++ and supporting rapid 60-day delivery.